2
2. Other Alarm Visual and Audible Indicators
Operational Mode
Visual Indications
Audible Indications
Action/Note:
normal (standby)
Green LED blink approx every 60 sec.
test (button press
when no alarm
condition is present)
•
4 patterns of Red/Amber/Green.
•
Test: Red LED blinks in time with
alarm pattern. Safety light will briefly
illuminate on model Q4000LDCS-
WCH or Q4000LDCS-WBH.
•
Green LED fade on/off at test
complete
•
Button press sound
•
Voice: "Testing, this is very loud. Press
now to cancel test. 5, 4, 3, 2, 1."
•
3 long beeps, Voice "Fire!", 3 long
beeps, Voice "Test Complete," Power
on/reset sound.
•
Voice "Test Cancelled" if button
pushed before test sequence
begins.
Perform Test/Hush button
press once a week to verify
proper alarm operation
Push/release button before
the countdown ends to
cancel test.
smoke Alarm
memory (unit has
experienced a
smoke alarm event
within the last hour)
Red and Amber LED alternate on
1 sec, every 10 sec.
After button push: "Smoke previously
detected" only on the initiating
alarm unit.
Push test button to clear
Alarm Memory. NOTE: stan-
dard test sequence will follow.
(Push/release button again to
cancel test).
smoke Alarm hush
mode, (smArt
hUsh control)
Red LED blinks every 2 sec.
After button push: "Hush Mode
Activated."
Smoke alarm pattern stops.
(If there is too much smoke to allow
Hush: Voice "Too Much Smoke, Alarm
cannot be Hushed" Smoke alarm
pattern continues.)
This feature is to be used
only when a known alarm
condition, such as smoke from
cooking, activates the alarm.
locate
None
After button push on non-initiating
unit, only initiating unit continues
alarm pattern.
Use this to quickly locate the
alarm source and determine if
alarm is nuisance or real.
smoke Alarm hush
mode cancelled
None
Voice message "Hush Mode
Cancelled."
When smoke levels drop
below the alarm threshold,
the voice message "Hush
Mode Cancelled" will occur .
Initiating Alarm,
(multiple alarms in
an interconnected
system)
Red LED will flash on the unit
initiating the alarm, but the red LED
on other interconnected units will
not flash.
Unit in Smoke Alarm mode.
Push button on initiating
alarm to silence that unit and
all interconnected units.