UG95_Hardware_Design Confidential / Released 34 / 72
3.7.2.3. Automatic Shutdown
The module will constantly monitor the voltage applie
d on the VBAT, if the voltage ≤ 3.5V, the following
URC will be presented:
+QIND: “vbatt”,-1
If the voltage ≥ 4.21V, the following URC will be presented:
+QIND: “vbatt”,1
The uncritical voltage is 3.3V to 4.3V, If the voltage > 4.3V or < 3.3V the module would automatically shut
down itself.
If the voltage < 3.3V, the following URC will be presented:
+QIND: “vbatt”,-2
If the voltage > 4.3V, the following URC will be presented:
+QIND: “vbatt”,2
The value of voltage threshold can be revised by AT command, refer to
document [1]
for details.
3.8. Reset the Module
The RESET_N can be used to reset the module.
Table 9: RESET_N Pin Description
Pin Name
Pin No.
Description
DC Characteristics
Comment
RESET_N
17
Reset the module
V
IH
max=2.1V
V
IH
min=1.3V
V
IL
max=0.5V
Pull-up to VRTC
internally
with 200kΩ
resistor.
Active low.
The module can be reset by driving the RESET_N to a low level voltage for more than 100ms and then
releasing.