UMTS/HSPA Module Series
UG95 Hardware Design
UG95_Hardware_Design Confidential / Released 53 / 72
Parameter
Description
Conditions
Min.
Typ.
Max.
Unit
I
VBAT
Peak supply
current (during
transmission slot)
Maximum power control level
on EGSM900.
1.8
2.0
A
USB_VBUS
USB insert
detection
2.5
5.0
5.25
V
5.3. Operating Temperature
The operating temperature is listed in the following table.
Table 24: Operating Temperature
Parameter
Min.
Typ.
Max.
Unit
Normal Temperature
-35
25
80
ºC
Restricted Operation
1)
-40~ -35
80 ~ 85
ºC
Storage Temperature
-45
90
ºC
1)
When the module works within the temperature range, the deviations from the RF specification may
occur. For example, the frequency error or the phase error would increase.
5.4. Current Consumption
The values of current consumption are shown as below.
Table 25: The Module Current Consumption
Parameter
Description
Conditions
Min.
Typ.
Max. Unit
I
VBAT
OFF state supply
current
Power down
70
uA
GSM/GPRS
Sleep (USB disconnected)
1.45
mA
NOTE