Smart Module Series
SC606T Series Hardware Design
SC606T_Series_Hardware_Design 91 / 116
7.3. Operating and Storage Temperatures
The operating and storage temperatures are listed in the following table.
Table 41: Operating and Storage Temperatures
1)
Within the operating temperature range, the module is 3GPP compliant.
7.4. Current Consumption
The current consumptions of the module in different conditions are listed in the following tables.
Table 42: SC606T-JP Current Consumption
I
VBAT
Peak supply current
(during a
transmission slot)
Maximum power control level
at EGSM900
-
1.8
3.0
A
USB_VBUS
4.0
5.0
6.0
V
VRTC
Supply voltage of a
backup battery
2.0
3.0
3.25
V
Parameter
Min.
Typ.
Max.
Unit
Operating temperature range
1)
-35
+25
+75
°C
Storage temperature range
-40
+90
°C
Description
Conditions
Typ.
Unit
OFF state
Power down
80
μA
WCDMA supply current
Sleep (USB disconnected)
@ DRX = 6
4.57
mA
Sleep (USB disconnected)
3.1
mA
NOTE