7.3. Operating and Storage Temperatures
The operating and storage temperatures are listed in the following table.
Table 46: Operating and Storage Temperatures
1)
Within the operating temperature range, the module is 3GPP compliant.
7.4. Current Consumption
The values of current consumption are shown below.
Table 47: SC200R-CE Current Consumption
I
VBAT
Peak supply
current (during
transmission slot)
Maximum power control level
at EGSM900
1.8
3.0
A
USB_VBUS
USB power supply
4.35
5.0
6.2
V
VRTC
Power supply
voltage of the
backup battery
2.0
3.0
3.25
V
Parameter
Min.
Typ.
Max.
Unit
Operating temperature range
1)
-35
+25
+75
ºC
Storage Temperature Range
-40
-
+90
ºC
Description
Conditions
Typ.
Unit
OFF state
Power down
13
μ
A
GSM/GPRS
Sleep (USB disconnected) @ DRX = 2
5.26
mA
NOTE