6.7. Electrostatic Discharge
The module is not protected against electrostatics discharge (ESD) in general. Consequently, it is subject
to ESD handling precautions that typically apply to ESD sensitive components. Proper ESD handling and
packaging procedures must be applied throughout the processing, handling and operation of any
application that incorporates the module.
The following table shows the module‘s electrostatics discharge characteristics.
Table 63: Electrostatics Discharge Characteristics (25ºC, 45% Relative Humidity)
6.8. Thermal Consideration
In order to achieve better performance of the module, it is recommended to comply with the following
principles for thermal consideration:
On customers’ PCB design, please keep placement of the module away from heating sources,
especially high power components such as ARM processor, audio power amplifier, power supply,
etc.
Do not place components on the opposite side of the PCB area where the module is mounted, in
order to facilitate adding of heatsink when necessary.
LTE-FDD B28 (10MHz) -98.0dBm
-98.7dBm -101.5dBm
-94.8dBm
LTE-TDD B40 (10MHz) -97.5dBm
-98.2dBm -101.2dBm
-96.3dBm
Tested Interfaces
Contact Discharge
Air Discharge
Unit
VBAT, GND
±5
±10
kV
All Antenna Interfaces
±4
±8
kV
Other Interfaces
±0.5
±1
kV
NOTE