background image

 EN

.

         

     

 

15 

 

 

Do  you  know  how  much  energy  you 
consume?  

 

 

The  Flush  1  Relay  monitors  and  reports 
energy  consumption  of  connected  devices 
in real time to your smart home app (your 
gateway  (hub)  needs  to  support  this 
feature). Know how much power your light, 
domestic water tank, iron, etc, is using.  
 
 
 

 

 

Want to control other devices in your 
Z-Wave  network  with  the  Flush  1 
Relay? 

 

 

 

Connect  the  Flush  1  Relay  with  other 
devices  in  your  network  to  remotely 
and  automatically  trigger  another  Z-
Wave  device.  And  have  other  Z-Wave 
devices  trigger  your  Qubino  Flush  1 
Relay. 
 
 

 

 

 

 

 

 

 

 

 

 

 

Содержание ZMNHAD1

Страница 1: ...USER MANUAL EN QUBINO FLUSH 1 RELAY The Qubino Flush 1 Relay is ideal for remotely controlling one light or electrical device door lock door opener small appliances etc...

Страница 2: ...trical box 13 2 4 Additional features of Flush 1 Relay which can make your life easier 14 3 Qubino Flush 1 Relay Advantages and Highlights 16 3 1 Advantages 16 3 2 Highlights 19 4 Package Contents 20...

Страница 3: ...additional features and parameters for you to play with We love helping people who enjoy creating new ideas for their home and then using their hard work and skill to turn those ideas into reality We...

Страница 4: ...us reading applications in residential and light commercial environments Mature proven and broadly deployed with over 50 million products sold worldwide Z Wave is by far the world market leader in wir...

Страница 5: ...stalling the device follow the instructions exactly The manufacturer GOAP d o o Nova Gorica shall not be legally responsible for any equipment damage or personal injury caused by incorrect installatio...

Страница 6: ...ZMNHAD5 50 60 Hz 916 0 MHz ZMNHAD6 50 60 Hz 868 4 MHz ZMNHAD7 50 60 Hz 919 8 MHz ZMNHAD8 50 60 Hz 865 2 MHz ZMNHAD9 50 60 Hz 922 5 MHz ZMNHADA 50 60 Hz 919 7 921 7 923 7 MHz ZMNHADB 50 60 Hz 868 1 MHz...

Страница 7: ...onnected device and can be paired with a digital temperature sensor sold separately It supports push button momentary switches and toggle switches default The connection of a digital temperature senso...

Страница 8: ...N 8 Flush 1 Relay supported functions Turn ON OFF W Measurement kWh Measurement Temperature Sensor Scene 1 Trigger Scene 2 Trigger Automatically turn ON OFF Associations Z Wave Repeater Auto inclusion...

Страница 9: ...ea for your next smart home project Of course there are countless of other options for how to use Qubino Flush 1 Relay to remotely control devices via your smartphone 2 1 Installation examples where F...

Страница 10: ...oom temperature The temperature sensor is sold separately for more info please see Qubino catalogue Product ordering code model number ZMNHEA1 Remotely trigger different scenes with two additional inp...

Страница 11: ...itching device on off and measuring power consumption of the connected device Remotely control an oven connected to a power socket Remotely control an iron connected to a power socket Remotely control...

Страница 12: ...onnected device Remotely measure power consumption of refrigerator connected to a power socket Remotely measure power consumption of microwave oven connected to a power socket Remotely measure power c...

Страница 13: ...control sanitary hot water recirculation pumps and remotely measure temperature of the sanitary hot water The temperature sensor is sold separately for more info check Qubino catalogue Product orderin...

Страница 14: ...n you d like The Flush 1 Relay offers the option to set the timing for irrigation for a specific amount of time internally it then automatically stops watering completely independent of your gateway s...

Страница 15: ...eway hub needs to support this feature Know how much power your light domestic water tank iron etc is using Want to control other devices in your Z Wave network with the Flush 1 Relay Connect the Flus...

Страница 16: ...r the ambient air or water temperature It s the only Z Wave switch in the world which offers this option With a connected sensor the user can monitor accurate measurements of the room temperature pool...

Страница 17: ...input I2 Welcome Home turn on all the lights in the house o Switch connected to input I3 Leaving Home turn off all the lights in the house Qubino guarantees 100 device quality Such high quality can b...

Страница 18: ...you open an inquiry with our support team this instantly shares the relevant device information we need to provide the best technical support possible For details please see the Device Information an...

Страница 19: ...fits in even the smallest flush mounting boxes Saves and restores the last status after a power failure Supports auto inclusion mode for quick set up Can automatically turn devices on and off after a...

Страница 20: ...EN 20 4 Package Contents Flush 1 Relay Device Installation Manual...

Страница 21: ...h Switch Bi stable switch Single pole double throw SPDT Two switches controlling the same light circuit of lights Two way switch Three way switch Two way switch Used when you have three or more switch...

Страница 22: ...22 Qubino devices are installed into flush mounting boxes behind the switches You can see some examples below For more information on how to install your device please refer to the Installation chapt...

Страница 23: ...sh 1 Relay with gateway hub Q I2 updates UI I3 updates UI W Measurements kWh Measurements Temperature Measurements Comments Domoticz V3 5877 Fibaro HC Lite v 4 100 Zipato 1 1 38 Vera edge v 1 7 2406 Z...

Страница 24: ...o not connect the device to loads exceeding the recommended values Connect the device exactly as shown in the provided diagrams Improper wiring may be dangerous and result in equipment damage Electric...

Страница 25: ...nt electrical shock and or equipment damage disconnect electrical power at the main fuse or circuit breaker before installation and maintenance Be aware that even if the circuit breaker is off some vo...

Страница 26: ...EN 26 Step 2 Installing the device Connect the device exactly according to the diagrams shown below Before Qubino installation...

Страница 27: ...EN 27 After Qubino installation Wiring with one switch...

Страница 28: ...EN 28 INSTALLATION WITH ON OFF SWITCH AND SCENE SWITCHES...

Страница 29: ...EN 29 INSTALLATION WITH 2 OR MORE SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...

Страница 30: ...EN 30 2 WAY SWITCH...

Страница 31: ...EN 31 MULTI WAY SWITCHES...

Страница 32: ...EN 32 INSTALLATION WHERE THERE IS NO NEUTRAL LINE N IN SWITCH BOX Before Qubino installation...

Страница 33: ...EN 33 After Qubino installation...

Страница 34: ...possible from metal elements as they may cause signal interference Do not shorten the antenna The device s antenna should be as upright as possible This ensures the device s operational range is maxi...

Страница 35: ...EN 35 Step 3 Turn ON the fuse...

Страница 36: ...EN 36 Step 4 Add the device to your Z Wave network For more details on how to include the device please refer to the Z Wave Inclusion chapter...

Страница 37: ...EN 37 Step 5 The Installation is now complete It s time to make your life more comfortable with the help of the Qubino Flush 1 Relay...

Страница 38: ...EN 38 7 2 Installing the device behind a socket Step 1 Turn OFF the fuse...

Страница 39: ...EN 39 Step 2 Install the device...

Страница 40: ...EN 40 Step 3 Turn ON the fuse Step 4 Add the device to your Z Wave network...

Страница 41: ...EN 41 Step 5 The Installation is now complete It s time to make your life more comfortable with the help of the Qubino Flush 1 Relay...

Страница 42: ...ected directly to power supply Install it and forget it there is no need to worry about changing the batteries like with most other Z Wave temperature sensors which run on batteries The temperature se...

Страница 43: ...EN 43 Temperature sensor installation example Step 1 Exclude the device if it is already connected to your Z Wave system Step 2 Switch of the power supply...

Страница 44: ...EN 44 Step 3 Connect the temperature sensor as shown below Step 4 Place the temperature sensor in the switch box...

Страница 45: ...EN 45 Step 5 Turn the fuse on Step 6 Re include the device to your network...

Страница 46: ...EN 46 Step 7 Start using the temperature sensor in connection with your device...

Страница 47: ...the device page for more information If you still don t find what you re looking for click on the link to Qubino technical support team They will be able to automatically read the serial and part num...

Страница 48: ...h button TS Temperature sensor terminal Wago 221 413 splicing connectors for L and N connection must be used only when connected to 230 VAC S Service button WARNING The S Service button must NOT be us...

Страница 49: ...e mode on your Z Wave gateway hub 2 Connect the device to the power supply with the temperature sensor already connected 3 Toggle the switch connected to the I1 terminal 3 times within 5 seconds OR If...

Страница 50: ...d 6 seconds 5 The device will be removed from your network but any custom configuration parameters will not be erased FACTORY RESET 1 Connect the device to the power supply 2 Within the first minute 6...

Страница 51: ...I3 input up to 16 nodes Group 9 Multilevel sensor report triggered at change of temperature sensor up to 16 nodes End point 1 Wall Switch I1 Group 1 Lifeline group 0 nodes allowed Group 2 Basic on of...

Страница 52: ...meter you can select between push button momentary and on off toggle switch types Values size is 1 byte dec default value 1 0 push button momentary 1 on off toggle switch Parameter no 2 Input 2 contac...

Страница 53: ...e deactivate ALL ON ALL OFF Functionality Flush 1 Relay device responds to commands ALL ON ALL OFF that may be sent by the primary or secondary gateway hub within the Z Wave network Values size is 2 b...

Страница 54: ...or milliseconds see Parameter no 15 Auto OFF timer enabled for a given amount of seconds or milliseconds Parameter no 12 Turn Load 1 Q On Automatically with Timer If Load Q is OFF you can schedule it...

Страница 55: ...this parameter applies to settings for Q load in all of the above parameters timer on timer off Parameter no 30 Restore on off status for Q load after power failure This parameter determines if on off...

Страница 56: ...ue set in this parameter compared to the previous Wattage reading starting at 1 the lowest value possible NOTE Power consumption needs to increase or decrease by at least 1 Watt to be reported REGARDL...

Страница 57: ...on the UI or enabled and displayed on the UI By enabling this endpoint setting it to be either a notification sensor or a binary sensor the user also selects a Notification Type and a Notification Eve...

Страница 58: ...arameter no 101 Enable Disable Endpoint I3 or select the Notification Type and the Notification Event Choose whether the Endpoint I3 is disabled and not shown on the UI or enabled and displayed on the...

Страница 59: ...y 9 GENERIC_TYPE_SENSOR_BINARY SPECIFIC_TYPE_NOT_USED Values size is 1 byte dec 9 Sensor binary NOTE 1 After changing the values of the parameter first exclude the device without setting the parameter...

Страница 60: ...tands for 10 00 C added to the actual measurement 1001 1100 Where 1001 stands for 0 1 C and 1100 stands for 10 0 C subtracted from the actual measurement Parameter no 120 Temperature Sensor Reporting...

Страница 61: ...104 F Z Wave operation range up to 30 m indoors 98 ft Dimensions WxHxD package 41 8x36 8x16 9 mm 79x52x22 mm 1 65x1 45x0 66 in 3 11x2 05x0 87 in Weight with package 28g 34g 0 98oz 1 20oz Electricity c...

Страница 62: ...d halogen lights 2300W 230VAC 1100W 110VAC LED bulb compact fluorescent bulb CFL low voltage halogen bulbs with electronic transformer LED 320W 230VAC 150W 110VAC CFL LVH Electronic transformer 800W 2...

Страница 63: ...PECIFIC_2 COMMAND_CLASS_DEVICE_RESET_LOCALLY_1 COMMAND_CLASS_POWERLEVEL_V1 COMMAND_CLASS_BASIC_V1 COMMAND_CLASS_SWITCH_ALL_V1 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_SENSOR_BINARY_V1 COMMAND_CLAS...

Страница 64: ...H_ALL_V1 COMMAND_CLASS_SWITCH_BINARY_V1 COMMAND_CLASS_METER_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_MARK COMMAND_...

Страница 65: ...ass ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_0N GENERIC_TYPE_SENSOR_NOTIFICATION SPECIFIC_TYPE_NOTIFICATION_SENSOR Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_VERSION_V2 COMMAND_...

Страница 66: ...ommand class is not supported by the device COMMAND_CLASS_SENSOR_MULTILEVEL_V7 This device can be included and operated in any Z Wave network with other Z Wave certified devices from any other manufac...

Страница 67: ...EN 67 COMMAND_CLASS_METER Default values o Rate Type 1 Import Scale 0 kWh...

Страница 68: ...les Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...

Страница 69: ...aste electrical and electronic equipment Directive do not dispose of this product as household waste or commercial waste Waste electrical and electronic equipment should be appropriately collected and...