11. Removing the device from a Z-Wave network
(Exclusion)
REMOVAL FROM A ZWAVE NETWORK (Z-WAVE EXCLUSION)
1. Connect the device to the power supply
2. Make sure the device is within direct range of your Z-Wave gateway (hub) or use a hand-held
Z-Wave remote to perform exclusion
3. Enable add/remove mode on your Z-Wave gateway (hub)
4. Toggle the switch connected to the I1 terminal 3 times within 5 seconds
OR
If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2
and 6 seconds
5. The device will be removed from your network but any custom configuration parameters will
not be erased
FACTORY RESET
1. Connect the device to the power supply
2. Within the first minute (60 seconds) the device is connected to the power supply, toggle the
switch connected to the I1 terminal 5 times within 5 seconds (5 times change switch state)
OR
If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than
6 seconds
ⓘ
By resetting the device, all custom parameters previously set on the device will return to
their default values, and the owner ID will be deleted. Use this reset procedure only when the
main gateway (hub) is missing or otherwise inoperable.
Содержание ZMNHAD1
Страница 20: ...EN 20 4 Package Contents Flush 1 Relay Device Installation Manual...
Страница 27: ...EN 27 After Qubino installation Wiring with one switch...
Страница 28: ...EN 28 INSTALLATION WITH ON OFF SWITCH AND SCENE SWITCHES...
Страница 29: ...EN 29 INSTALLATION WITH 2 OR MORE SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...
Страница 30: ...EN 30 2 WAY SWITCH...
Страница 31: ...EN 31 MULTI WAY SWITCHES...
Страница 32: ...EN 32 INSTALLATION WHERE THERE IS NO NEUTRAL LINE N IN SWITCH BOX Before Qubino installation...
Страница 33: ...EN 33 After Qubino installation...
Страница 35: ...EN 35 Step 3 Turn ON the fuse...
Страница 38: ...EN 38 7 2 Installing the device behind a socket Step 1 Turn OFF the fuse...
Страница 39: ...EN 39 Step 2 Install the device...
Страница 40: ...EN 40 Step 3 Turn ON the fuse Step 4 Add the device to your Z Wave network...
Страница 45: ...EN 45 Step 5 Turn the fuse on Step 6 Re include the device to your network...
Страница 46: ...EN 46 Step 7 Start using the temperature sensor in connection with your device...
Страница 67: ...EN 67 COMMAND_CLASS_METER Default values o Rate Type 1 Import Scale 0 kWh...