![QUBINO ZMNHAD1 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/qubino/zmnhad1/zmnhad1_user-manual_3579860060.webp)
EN
.
60
Parameter no. 110
–
Temperature Sensor Offset Settings
Set value is added to or subtracted from the actual measured value to adjust the temperature
report sent by an external sensor (sold separately). This parameter only applies to Celsius
temperature unit (the Fahrenheit unit is currently not supported).
Values (size is 2 byte dec):
•
default value 32536
•
32536 - Offset is 0
°C
.
•
1 - 100 - Where 1 stands for 0.1 and 100 stands for 10.00
°C
added to the actual
measurement.
•
1001 - 1100
–
Where 1001 stands for -0.1
°C
and 1100 stands for -10.0
°C
subtracted
from the actual measurement.
Parameter no. 120
–
Temperature Sensor Reporting Threshold
If an external digital temperature sensor (sold separately) is connected to the device, it reports
temperature readings based on the threshold defined in this parameter. This parameter only
applies to the Celsius temperature unit (the Fahrenheit unit is currently not supported).
Values (size is 1 byte dec):
•
Default value 5 = 0.
5°C
•
0
–
Reporting disabled
1 - 127 = Where 1 stands for 0.1
°C
and 127 stands for 12.7
°C
Содержание ZMNHAD1
Страница 20: ...EN 20 4 Package Contents Flush 1 Relay Device Installation Manual...
Страница 27: ...EN 27 After Qubino installation Wiring with one switch...
Страница 28: ...EN 28 INSTALLATION WITH ON OFF SWITCH AND SCENE SWITCHES...
Страница 29: ...EN 29 INSTALLATION WITH 2 OR MORE SWITCHES CONTROLLING THE SAME LIGHT Before Qubino installation...
Страница 30: ...EN 30 2 WAY SWITCH...
Страница 31: ...EN 31 MULTI WAY SWITCHES...
Страница 32: ...EN 32 INSTALLATION WHERE THERE IS NO NEUTRAL LINE N IN SWITCH BOX Before Qubino installation...
Страница 33: ...EN 33 After Qubino installation...
Страница 35: ...EN 35 Step 3 Turn ON the fuse...
Страница 38: ...EN 38 7 2 Installing the device behind a socket Step 1 Turn OFF the fuse...
Страница 39: ...EN 39 Step 2 Install the device...
Страница 40: ...EN 40 Step 3 Turn ON the fuse Step 4 Add the device to your Z Wave network...
Страница 45: ...EN 45 Step 5 Turn the fuse on Step 6 Re include the device to your network...
Страница 46: ...EN 46 Step 7 Start using the temperature sensor in connection with your device...
Страница 67: ...EN 67 COMMAND_CLASS_METER Default values o Rate Type 1 Import Scale 0 kWh...