background image

© Quatro Air Technologies| MAY 2019 | All rights reserved | 

iVAC Premium Series Operation and Maintenence Manual

Page 8

Installation

Installation

1. 

Open the lower access door at the front of the unit. 

 

  

2.  Remove all accessories from the drawer.

3. 

Verify that the main filter did not shift in shipping. 

DO NOT OPERATE UNIT UNLESS ALL FILTERS ARE IN PLACE.

4. 

Install the inlet plate on the inlet opening in back (opening without the grill) using the 4 Phillips head screws, supplied.

 

5. 

Connect the hose(s) to the workstations. If using plastic pipe (ABS/PVC),see the proper grounding instructions below. 

 

Tees connect directly to the inlets on the iVAC. The hoses slide into the tees.

6. 

 V

ERIFY VOLTAGE BEFORE CONNECTING 

and then connect the power cord to the unit and then to the power 

source.

• 

 ONLY USE THE POWER CORD SUPPLIED WITH THE EQUIPMENT.

• 

Always plug the unit directly into the wall outlet. Do not use extension cords or power bars.

• 

Ideally the unit should be plugged into it’s own dedicated circuit. 

• 

The system is designed to be constantly powered (plugged in). The system will not function correctly and may get 

damaged if power source is used to control the operation. See "

Controls

" on page 10

 for more info. 

For information about remote operation see 

"

Controls

" on page 10

Important Notes

• 

The HEPA filter in this system is 

NOT

 cleanable. It will need to be removed and disposed of and replaced periodically. 

• 

The Main filter should be replaced after approx 24 months of use. 

•  See "

Filter Service and Replacement

" on page 15

 for more info.

Содержание Premium iVAC Series

Страница 1: ...Quatro Air Technologies MAY 2019 All rights reserved Operation and Maintenance Manual Premium SeriesTurbine Dust Collectors iVAC Compact 2 0 iVAC Infinity 2 0 iVAC TWIN 2 0...

Страница 2: ...oper Function of Controls 10 iSeries Controls and Alarms Status Conditions 10 LED Diagnostics Table R17 0 And Higher iVac 11 Normal Manual Operation 12 Variable Digital Speed Control and AUTOFLOW 12 R...

Страница 3: ...nd Maintenance Manual Contents Page 3 Filter and Dust Tray Access 17 Motor Service and Replacement 23 LED Diagnostic Table Service Motor s Alerts 23 Motor Access 23 Replacement Instructions 24 Trouble...

Страница 4: ...ter particles captured in the filter to fall down into tray 4 HEPA filter captures and holds fine particles protecting the motor and ensuring a clean output 5 High pressure blower section overcomes pr...

Страница 5: ...Manual Page 5 Introduction Contact Information Phone 1 877 978 2876 US and Canada 1 514 630 4444 local calling Fax 1 514 630 4454 email General inquiries info quatroair com Technical Support tech quat...

Страница 6: ...LWAYS turn system off and disconnect power prior to accessing unit replacing filters or servicing motor s To reduce the risk of electric shock do not expose to excessive moisture water or rain Do not...

Страница 7: ...stem Contents System Contents All iVAC systems include Operation and Maintenance Manual Power Cord Appropriate Size Inlet Plate 2 B Bench Series units include 6 12 or 25 6ft of 1 5 diameter hose 6ft r...

Страница 8: ...e tees 6 VERIFY VOLTAGE BEFORE CONNECTING and then connect the power cord to the unit and then to the power source ONLY USE THE POWER CORD SUPPLIED WITH THE EQUIPMENT Always plug the unit directly int...

Страница 9: ...complete the connection to the ground Wires over the irregularities of fittings especially at Y s or T s could form traps for particles Therefore bypass the fittings by running the wires to the outsi...

Страница 10: ...ower On Off Speed Up and Speed Down Buttons It also features a series of LEDs that indicate the status of the filter s and motor s and inform you of any alarms These alarms are accompanied by an audib...

Страница 11: ...ET ALERT See Motor Service and Replacement on page 23 SOLID Beep Every 5 Min Motor s Service Required IMMEDIATELY Quick Change Brush Motors ONLY Replace Brushes IMMEDIATELY And RESET ALERT See Motor S...

Страница 12: ...Second Low System Pressure Abnormally Low Pressure Unit will BEEP Shutdown In 5 Seconds Unit Will Continue To Shutdown Unit Until The Issue Is Addressed Motor s Not Operating Due To Service Required...

Страница 13: ...mporarily BLOCK OR DISENGAGE all other functions To initiate Press POWER On Off button to start unit System ON LED will FADE In Out unit will start When you finish using this feature press POWER On Of...

Страница 14: ...XCEED 30V AC DC To enable the remote system startup for either remote option first plug the system into power and then connect remote cable Then simply have the other piece of equipment close short th...

Страница 15: ...Menu on page 16 If operating more than 120 minutes at a time or in a heavy dust environment Quatro recommends using the OnLine cleaning mode OnLine Filter Cleaning Default Setting NOTE Recommended set...

Страница 16: ...Motor s LED indicates filter cleaning frequency is set to 15 minutes L3 Service Filters LED indicates filter cleaning mode is set to 30 minutes L4 Auto Cleaning Filter LED indicates filter cleaning mo...

Страница 17: ...act iVAC 1 and iVAC 2 MAIN FILTER Removing Filters 1 Remove the dust debris tray 2 Loosen the plastic wingnuts located below the filter accessible from dust debris tray section Debris Dust Tray Access...

Страница 18: ...can be removed and emptied On the iV iVL iVT and iVTL models the dust tray slides on v tracks and on the iVS and iVSL models the dust tray rest on the floor of the unit Main Filter Cleaning and Repla...

Страница 19: ...disconnect 3 Remove the dust tray to expose the wingnuts that secure the Main Filter Hold Down bracket 4 Remove the main filter support bracket by removing the wingnuts 5 Remove and replace the main f...

Страница 20: ...ates to do so 1 Unplug power cord and open filter access door s 2 Unplug FCS electrical quick disconnect 3 Remove the dust tray expose the wingnuts that secure the Main Filter Hold Down bracket 4 Remo...

Страница 21: ...l quick disconnect 3 Remove the dust tray expose the wingnuts that secure the Main Filter Hold Down bracket 4 Remove the main filter support bracket by removing the wingnuts 5 Remove the 7 16 locking...

Страница 22: ...l rights reserved iVAC Premium Series Operation and Maintenence Manual Page 22 Filter Service and Replacement Replacement FCS Part Numbers Qty Description Part 1 Replacement FCS Motor 120V AR123 16 1...

Страница 23: ...17 0 And Higher iVac on page 11 Motor Access WARNING Switch unit off and unplug power cord from wall before servicing the motor s The motor access panel is located on the top of the unit NOTE Infinity...

Страница 24: ...ictures below WARNING THIS STEP IS PARTICULARLY IMPORTANT FOR Infinity MOTORS If the bracket is installed incorrectly it may result in a short to ground for the brush contacting the bracket The curved...

Страница 25: ...c1 Quantity Required iVac 2 120V Infinity iVCL iV1L iV2L AR175 1 2 230V Infinity iVCL iV1L iV2L AR176 1 2 120v Brushless Motor AB045 16 1 230v Brushless Motor AB045 26 1 ALWAYS Replace Both Motors At...

Страница 26: ...l Replace motor Motor shuts off Motor overheated tripped on thermal cutout Motor motor brushes past service life Switch power off unplug wait till motor cools replace filters verify blockage Replace m...

Страница 27: ...4 22m3 hr 120 130cfm 204 22m3 hr 240 260cfm 204 22m3 hr Unit Dimensions HxWxD 21 75x9 8x17 553x248x432 25x14 4x16 2 633x366x412 26x15 9x19 8 661x404x503 Voltage Phase Frequency Current 115 1 60 7 Amps...

Страница 28: ...C 2 Power Cord 120v E500 1 1 1 Power Cord Euro 230V E130 1 1 1 Replacement Black Door Knob Kit 2 pcs AR097 1 1 1 Replacement HEPA Filter Support Knob 2 set AR034 1 1 n a Rubber Grommets for Main Filte...

Страница 29: ...O BE CONSTANTLY POWERED PLUGGED IN USE THE ON OFF ONLY SWITCH TO TURN THE SYSTEM ON and OFF ALWAYS SWITCH THE POWER OFF BEFORE UNPLUGGING THE SYSTEM FROM THE MAIN POWER SOURCE OR BEFORE CUTTING POWER...

Отзывы: