© Quatro Air Technologies| MAY 2019 | All rights reserved |
iVAC Premium Series Operation and Maintenence Manual
Page 8
Installation
Installation
1.
Open the lower access door at the front of the unit.
2. Remove all accessories from the drawer.
3.
Verify that the main filter did not shift in shipping.
DO NOT OPERATE UNIT UNLESS ALL FILTERS ARE IN PLACE.
4.
Install the inlet plate on the inlet opening in back (opening without the grill) using the 4 Phillips head screws, supplied.
5.
Connect the hose(s) to the workstations. If using plastic pipe (ABS/PVC),see the proper grounding instructions below.
Tees connect directly to the inlets on the iVAC. The hoses slide into the tees.
6.
V
ERIFY VOLTAGE BEFORE CONNECTING
and then connect the power cord to the unit and then to the power
source.
•
ONLY USE THE POWER CORD SUPPLIED WITH THE EQUIPMENT.
•
Always plug the unit directly into the wall outlet. Do not use extension cords or power bars.
•
Ideally the unit should be plugged into it’s own dedicated circuit.
•
The system is designed to be constantly powered (plugged in). The system will not function correctly and may get
damaged if power source is used to control the operation. See "
for more info.
For information about remote operation see
Important Notes
•
The HEPA filter in this system is
NOT
cleanable. It will need to be removed and disposed of and replaced periodically.
•
The Main filter should be replaced after approx 24 months of use.
• See "
Filter Service and Replacement
for more info.