© Quatro Air Technologies| MAY 2019 | All rights reserved |
iVAC Premium Series Operation and Maintenence Manual
Page 19
Filter Service and Replacement
2.
Unplug FCS electrical quick disconnect.
3.
Remove the dust tray to expose the wingnuts that secure the Main Filter Hold Down bracket.
4.
Remove the main filter support bracket by removing the wingnuts.
5.
Remove and replace the main filter (the main filter can also be removed,
cleaned and reinstalled).
On iV and iVT units have ensure the Main filter is up against the filter guides
and not sitting on top of them.