3
rd
Generation Compact RDMS
TM
Telemetry Receiver
19
Quasonix, Inc.
4.3.1
Tier 0 (PCM/FM), Tier I (SOQPSK-TG), and Tier II (Multi-h CPM) Commands
The following table describes all receiver user commands. Listed are the command code, name, description of the
command, whether specific options must be ordered or the command is standard on all receivers, basic or advanced
command, and whether the command is restricted to specific waveform modes.
Multiple commands may be typed on a command line if they are separated by a semicolon “;”. There is a limit of
256 characters per command line, including semicolons. Commands with no parameters request status only.
Refer to command HA in section 4.3.2.23 for specific help in reading the command sets.
Refer to section 4.3.2 for additional command set detail and examples. This information is also available in the
command Help.
For example:
PCM/FM>FR 2200.5; BR 6.000; AGC
results in the following:
Frequency set to 2200.5 MHz
Bit Rate set to 6.000 Mbps
and status for all AGC parameters are displayed as:
AGC control enabled
AGC control mode RF
AGC automatic mode select enabled
AGC zero mode Auto
AGC zeroed at -110.22 dBm (13.38 dB attenuation)
AGC auto zero hold threshold 0.000 dB
AGC auto zero time constant 0.250 seconds
AGC loop total power 13.375 dB
Bulk attenuator AGC control enabled, switched out
Ctrl Y repeats the command sequence without having to retype the commands.