3
rd
Generation Compact RDMS
TM
Telemetry Receiver
39
Quasonix, Inc.
<p>
sets the channel polarity to one of the values below:
•
{0|+} - Active high (normal)
•
{1|-} - Active low (inverted)
OR
S <s>
sets the channel scale to a value between -128.0000 and 127.9961
OR
O <o>
sets the channel offset to a value between -1.0000 and 0.9995
E <e>
sets the channel enable to enabled or disabled
•
0 - Disabled
•
1 - Enabled
Examples:
ALO C AGC
Sets the channel to Channel C (AGC) with AGC output
ALO D 1
Sets the channel to Channel D (Aux Analog B Out) with polarity active low
(inverted)
ALO A S 98.6543
Sets the channel to Channel A (Demodulated AM) with channel scale set to
98.6543
ALO B E 0
Sets the channel to Channel B and disables the channel
ALO -V ?
- Shows extended Help for the AHO command
Example:
ALO
Displays current low speed (ACU) output status settings (enabled/disabled and output frequency)
low speed (ACU) Channel A (AM)
Source Demodulated AM
Scale - 1.0000
Offset - 0.0000
Polarity - High (+)
low speed (ACU) Channel B (Aux Analog A Out)
Source Fixed value 0
Scale - 1.0000
Offset - 0.0000
Polarity - High (+)
low speed (ACU) Channel C (AGC)
Source AGC output
Scale - 1.0000