Bypass Valve Information
Automatic Bypass Information
The automatic bypass is controlled by the settings
chosen on the control valve.
The keys on the bypass valve serve no function when
connected to the control valve and should not be used.
Bypass stages
The bypass stage used by the automatic bypass is
determined by the water hardness setting selected during
programming of the control valve.
Bypassing Stage III - water hardness 200-300 mg/L
Bypassing Stage II - water hardness 301-425 mg/L
Bypassing Stage I - water hardness 426-550 mg/L
Turning Off Bypass
The control valve controls the bypass settings. To change the bypass settings, press and hold both up
and
down
keys simultaneously for 3 seconds to unlock the key pad.
Press Menu
key. Display shows “Set Softener Para.”
“Set Time of Day” is selected automatically.
Press Down key until can select “Bypass set” as shown in Fig. 3A.
Bypass is set to Intelligent Bypass during normal service as shown in Fig. 3B.
If you do not want unsoftened water to be able to flow during your
softener’s regeneration, press Down key to select “No bypass”.
If you want to allow water to fully bypass the water softener, press Down key to
select “Fully Bypass.”
Press Menu key to return to In-Service Status.
Set Softener Para.
Set Regen. Time
Set Water Hardness
Bypass Set
Bypass set
Intelligent bypass
No bypass
Fully bypass
Fig. 3A
Fig. 3B
Top view of bypass assembly