11
Assembly Instructions
Inlet elbow
connector
Outlet elbow
connector
Signal wire
Power Cord
Plug
Power
Cord Plug
Brine line
connector
Bypass
Drain connector
STEP 6: Connect overflow drain line to brine tank
A.
Locate overflow elbow (in Parts Bag A.) Remove nut from
threading. Insert drain elbow (1) in bottom half of brine
tank below brine line as shown in Figure 1.2.
B. Replace nut on drain elbow inside of brine tank. Attach
clear drain tubing (2) to the drain elbow. Secure with hose
clamp (form Owner’s Manual Zip-Lock Bag).
C.
Secure the clear drain tubing over a floor drain or other
suitable drain. Check your local codes to ensure compliance.
Leave an air gap of about 1 1/2” between the end of the
hose and the drain. An air gap is necessary to prevent
backflow of sewer line.
Overflow
elbow
Hose
clamp
FIGURE 1.2
1
2
STEP 7: Connect Inlet elbow connector to home water supply.
STEP 8: Connect Outlet elbow connector to home plumbing.
STEP 9: Flush water lines and program control valve as on following pages before first use.