After Control Valve has been programmed, perform the following steps before first use:

Open a water line and let water flow until water runs clear.

Press and hold both up   

  and down  

  keys simultaneously for 3 seconds to unlock the key pad.

Press Regen   key to advance through each cycle, following the below instructions.

When you press the Regen key, the screen will display “motor running” as it positions the ceramic disc. Once 

“motor running” disappears and the next phase is displayed, press manual return key to advance to the next phrase.

1 - Backwash - lets air out of  the drain line. Process will take 8-10 minutes to purge the system.

Press Regen key to advance to the next phase, brine and slow rinse.

2 - Brine and slow rinse - verify the air check valve is closed by listening to be sure no air is being drawn into the 

system. Press Regen key to advance to the next phase, brine refill.

3 - Brine refill - This stage will fill the brine tank with the correct amount of  water. Allow the brine refill phase to 

run, do not advance past this phase until it is complete. After this phase has completed, press Regen key to advance 

to Fast rinse, then press Regen key again to return to In Service position.

Add salt to the brine tank (40 pound minimum, 120 pound maximum).

Note:

 We recommend using water softener salt, 99% pure.

Install brine tank cover.

Turn on a faucet away from the installation location. Turn off  faucet when plumbing lines have been purged.

Your water softener should now be fully operational.

To verify that your water softener is functioning correctly, take a water sample test to verify hardness reduction.

Manual Regeneration

To force a manual regeneration:

Press and hold up  

 and down  

  keys for five seconds until a beep sounds and the button lock indicator light 

turns off.

Press Regen key      to start the backwash.

Press Regen key again to move to Brine and Slow Rinse (60 minutes)

Press Regen key again to move to Brine Refill (13 minutes)

Press Regen key again to move to Fast rinse (10 minutes)

Press Regen key again to return to In-Service.

Содержание TIER1-AR2

Страница 1: ...Owner s Manual QUANTUM TIER1 AR2 WaterSoftener...

Страница 2: ...2 Table of Contents What s Included 3 Operating Conditions 5 Assembly Instructions 7 Master Programming 13 Care and Maintenance 17...

Страница 3: ...following 1 Control Valve with Bypass 2 Resin Tank 3 Parts Bags 4 Owner s Manual Zip lock Bag 5 Brine Tank and Brine Valve Assembly 1 Control Valve Upper Distributor 5 Brine Tank 3 Parts Bags 2 Resin...

Страница 4: ...d professional to ensure all local munici pal and state codes are met Do not use the water softener with water that is unsafe or of unknown quality Do not use the brine tube injector body or other con...

Страница 5: ...pper Distributor F Brine Valve G Brine Well H Control Valve Power Cord Parts Bag A includes 1 Brine Well Overflow Elbow 2 Brine Well Bracket 3 Blue C Clip 1 2 3 Parts Bag B includes 1 Master O Ring 3...

Страница 6: ...ipping cap a master O Ring and a piece of tape covering the riser tube This is to prevent resin from entering the riser tube during shipping The cap master O Ring and tape must be removed and discarde...

Страница 7: ...Bag Insert into bottom of control valve as shown below B Connect the upper distributor to bottom of control valve line up slots and twist as shown below C Center the riser pipe within the resin tank D...

Страница 8: ...clips to secure bypass B Connect inlet and outlet elbow connectors to pipe connection end of bypass valve Install plastic clips C Connect the signal wire ends from control valve and bypass Tighten nu...

Страница 9: ...Replace nut on bracket outside of hole in tank E Feed PVC tubing 3 from outside the brine tank through the hole in the bracket Push tubing firmly into quick connect fitting on brine valve F When full...

Страница 10: ...cure the clear drain tubing over a floor drain or other suitable drain Leave an air gap of about 1 1 2 between the end of the hose and the drain An air gap is necessary to prevent backflow of sewer li...

Страница 11: ...e tank Attach clear drain tubing 2 to the drain elbow Secure with hose clamp form Owner s Manual Zip Lock Bag C Secure the clear drain tubing over a floor drain or other suitable drain Check your loca...

Страница 12: ...programming instructions begin on page 13 Please review all settings and adjust as necessary for your water hardness to ensure that the water softener will work most effectively for your needs Display...

Страница 13: ...y to adjust hour value 3 Press Menu key Minute value 00 flashes Press Up or Down key to adjust minute value 4 Press Menu key to return to first screen Water Hardness 1 Press Down key to select Set Wat...

Страница 14: ...allons remaining to be used before triggering a regeneration Note Typical water usage is calculated at 75 gallons per person per day Screen 2 Button lock key Current time of day in 24 hour clock Curre...

Страница 15: ...fill the brine tank with the correct amount of water Allow the brine refill phase to run do not advance past this phase until it is complete After this phase has completed press Regen key to advance...

Страница 16: ...ass settings To change the bypass settings press and hold both up and down keys simultaneously for 3 seconds to unlock the key pad Press Menu key Display shows Set Softener Para Set Time of Day is sel...

Страница 17: ...te the softener Caution Liquid brine will irritate eyes skin and open wounds Gently wash exposed areas with fresh water Keep children away from water softener Product Care To retain the attractive app...

Страница 18: ...ner SOMETHING NOT RIGHT Our Support Team is here to assist you We re happy to answer any questions you may have Quality Water Treatment Quantum Authorized Dealer 866 278 4130 www QualityWaterTreatment...

Отзывы: