Chapter 3: Basic System Operations
Shutting Down a Single MDC Node of the StorNext M660
StorNext M660 Metadata Appliance Hardware Guide
55
Shutting Down a Single MDC Node of the StorNext
M660
To shut down a single MDC node:
1
Open an SSH connection to the MDC node you wish to access using
either IP address
10.17.21.1
or
10.17.21.2
on the MDC/Metadata
network.
Note:
Use the IP addresses assigned within the network if
different from the defaults used here.)
2
Enter
stornext
for the username at the prompt.
3
Enter the
stornext
password. The default password is “password”,
but may have been changed after initial configuration.
4
At the command prompt enter the following to gain root user
access:
5
Enter the password for the
stornext
user account again when
prompted.
6
Press Enter.
7
If you are connected to the MDC node currently acting as the
primary, enter the following (if you are connected to the MDC node
currently acting as the secondary, issue the command provided in
Step 11
):
8
Wait until the MDC node currently acting as primary becomes the
secondary
, and leave your SSH connection to this node open. (Time
may vary.)
sudo rootsh
service cvfs fullstop
Содержание StorNext M660
Страница 1: ...TIP How to Navigate this PDF Hardware Guide StorNext M660 Metadata Appliance 6 67639 01 Rev G...
Страница 6: ...Contents vi StorNext M660 Metadata Appliance Hardware Guide...
Страница 17: ...Chapter 1 Introduction Product Safety Statements StorNext M660 Metadata Appliance Hardware Guide 11...
Страница 18: ...Chapter 1 Introduction Product Safety Statements 12 StorNext M660 Metadata Appliance Hardware Guide...
Страница 86: ...Chapter 4 Contacting Quantum 80 StorNext M660 Metadata Appliance Hardware Guide...