Chapter 3: Connecting Hosts
Obtaining IP Values
QX and QXS Setup Guide
120
Parameter
Value
Translations
None
Columns
80
Parameter
Value
Connector
COM3 (for example)
1,2
Baud rate
115,200
Data bits
8
Parity
None
Stop bits
1
Flow control
None
Table 10:
Terminal emulator connection settings
1
Your server or laptop configuration determines which COM port is used for Drive Array USB Port.
2
Verify the appropriate COM port for use with the CLI.
5. In the terminal emulator, connect to controller A.
6. Press
Enter
to display the CLI prompt (
#
).
The CLI displays the system version, MC version, and login prompt:
a. At the login prompt, enter the default user
manage
and press
Enter
.
b. At the password prompt, enter the default password
!manage
and press
Enter
.
If the default user name, password, or both have been changed for security reasons, enter the secure
login credentials instead of the defaults.
7. At the prompt, enter the following command to set the values you obtained in
port, first for controller A, and then for controller B:
set network-parameters ip
address
netmask
netmask
gateway
gateway
controller a|b
where:
l
address
is the IP address of the controller
l
netmask
is the subnet mask
l
gateway
is the IP address of the subnet router
l
a|b
specifies the controller whose network parameters you are setting
For example:
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway 192.168.0.1
controller a