18
NORMAL OPERATION
• Flow rate to activate the water heater
: 3.0 LITRES per minute
• Flow rate to keep the water heater running
: 2.5 LITRES per minute
WITHOUT REMOTE CONTROLLER
1
.
Open a hot water tap.
2
.
Mix cold water with the hot to get
the suitable temperature water.
3
.
Close the hot water tap.
NOTE:
The water temperature is set at
50 °C
from the factory.
If you desire to change the set temperature without remote controller, refer to diagram below.
Temperature set
40 °C
45 °C
50 °C
DEFAULT
55 °C
60 °C
Error
70 °C
Error
8
7
6
5
ON
OFF
TMP1
TMP2
TMP3
8
7
6
5
ON
OFF
TMP1
TMP2
TMP3
8
7
6
5
ON
OFF
TMP1
TMP2
TMP3
8
7
6
5
ON
OFF
TMP1
TMP2
TMP3
8
7
6
5
ON
OFF
TMP1
TMP2
TMP3
8
7
6
5
ON
OFF
TMP1
TMP2
TMP3
8
7
6
5
ON
OFF
TMP1
TMP2
TMP3
8
7
6
5
ON
OFF
TMP1
TMP2
TMP3
• Only change the switches with dark squares.
• DO NOT adjust other switches.
WITH ONLY MAIN REMOTE CONTROLLER INSTALLED
1.
Press the ON/OFF button. And then ensure the priority lamp is
lit and displays the set temperature on the remote controller.
2. SET PREFERRED TEMPERATURE. WHEN ADJUSTING THE SET
TEMPERATURE, THE MAIN ALLOWS THE OUTPUT TEMPERA
-
TURE FROM THE WATER HEATER TO BE ADJUSTED WITHIN THE
RANGE OF 37 °C to 55 °C. (Please refer to P. 14.)
3.
Open a hot water tap, and ensure the BURNER ON lamp is lit.
Mix cold water with the hot if you need.
4.
Close the hot water tap, and ensure the BURNER ON lamp is
OFF.
PRIORITY
BURNER ON
ON/OFF
PRIORITY
MADE IN JAPAN
Main
4 0
COOL
H O T
Priority
button
ON/OFF
Set temperature
display
Set temperature
adjust button
Burner on
lamp
lamp
Priority
button
MAIN