12
WATER CONNECTIONS
Drain plug
Filter
Hot water
outlet
Cold water
inlet
Gate or ball
valve on inlet
WARNING
Do not reverse the hot outlet and cold
supply line connections to the Water
Heater as this will cause your heater to
operate improperly.
• All pipes, pipe fittings, valves and other components, including soldering materials, must be suitable for
potable water systems.
• A manual shut off valve must be installed on the cold water inlet to the water heater between the main
water supply line and the water heater.
• Only a gate valve or a ball valve is to be used on the cold water supply.
• No stop taps or check valves are to be used as this will void the warranty and damage the water heater.
• Check the cold water pressure and if above 1000 kPa, an approved pressure limiting valve must be
fitted.
• Before installing the water heater, flush the water line to remove all debris, and after installation is
complete, purge the air from the line. Failure to do so may cause damage to the heater.
• There is a wire mesh filter to discourage debris from entering your heater. Clean filter after initial
installation to ensure no debris from the pipe work has clogged it.
3. REMOVE BY TURNING
COUNTERCLOCKWISE
AND THEN CLEAN AND
REPLACE
1. TURN OFF THE WATER
INLET SUPPLY VALVE.
2. OPEN A HOT WATER
TAP TO RELEASE THE
LINE PRESSURE.
filter
NOTE: This filter must be cleaned as part of regular maintenance.