Chapter 4: Operations
Diagnostic and Maintenance Functions
Quantum LTO-5 HH SAS Model C User’s Guide
57
1
Place the drive in Maintenance Mode. For instructions, see
2
Press the Unload Button once per second until F appears in the SCD.
(If you cycle past the desired code, press the Unload Button once
per second until the code reappears.)
3
Press and hold the Unload Button for three or more seconds, then
release it to select the function. The SCD changes to a flashing C.
4
Insert a scratch (blank) data cartridge. The SCD changes to a
flashing F and the tape drive runs the tests.
• If no error is detected, the diagnostic will loop and begin again.
To stop the loop, press the Unload Button for one second and
release. When the diagnostic ends, 0 temporarily appears in the
SCD, and the tape drive exits Maintenance Mode.
• If an error is detected, the Fault light flashes and the drive posts
an error code to the SCD. To determine the error, locate the
code in
Appendix A, Error Codes and Messages
. To clear the
error either turn the power off and then on again, or reboot the
drive by pressing and holding the Unload Button for 10
seconds.
Function Code H: Test
Head
Approximate Run Time = 12 minutes per loop
Total Number of Loops = 10
Function Code H performs tests to ensure that the tape drive's head and
tape-carriage mechanics work correctly.
Once you begin this test, the diagnostic begins the loop sequence. Time
the first loop by pressing the Unload Button once to stop the diagnostic
after the completion of the first loop, then record the time it takes for
the test to complete. Compare the recorded time with the Approximate
Run Time above. If the test runs successfully but the execution time is
significantly longer than the Approximate Run Time, run
on page 56. If the Write Performance Test
fails, replace the media and exit maintenance mode.
Press the Unload Button to stop the diagnostic and exit maintenance
mode. Pressing the Unload Button once will abort the test at the end of
the current test loop. Pressing the Unload Button twice will abort the
test immediately. Wait for the drive to rewind the tape and unload the
cartridge.
Содержание LTO-5 HH SAS C
Страница 1: ...Technical Reference Manual Quantum LTO 5 HH SAS Model C User s Guide 6 68131 01 Rev A...
Страница 36: ...Chapter 3 Installation Updating Firmware 30 Quantum LTO 5 HH SAS Model C User s Guide...
Страница 84: ...Chapter 5 Media Disposing of Tape Cartridges 78 Quantum LTO 5 HH SAS Model C User s Guide...
Страница 90: ...Chapter 6 Troubleshooting Pre Call Checklist 84 Quantum LTO 5 HH SAS Model C User s Guide...
Страница 100: ...Appendix A Error Codes and Messages 94 Quantum LTO 5 HH SAS Model C User s Guide...
Страница 102: ...Appendix B Tape Alert Flags 96 Quantum LTO 5 HH SAS Model C User s Guide...
Страница 118: ...Glossary 112 Quantum LTO 5 HH SAS Model C User s Guide...