Chapter 9: Troubleshooting
Monitoring the Lattus A10 Access Node for Alerts
40
Lattus A10 Access Node User’s Guide
Caution:
When correcting a power supply mismatch, replace
only the power supply with the flashing indicator.
Swapping the opposite power supply to make a
matched pair can result in an error condition and
unexpected system shutdown. To change from a
High Output configuration to a Low Output
configuration or vice versa, you must power down
the system.
AC power supplies support both 220 V and 110 V
input voltages. When two identical power supplies
receive different input voltages, they can output
different wattages, and trigger a mismatch.
•
Hard Drive Activity and Status Indicators
: (See information for
these LEDs in the section
•
NIC Link and Activity Indicators
:
•
Link and activity indicators are off
= The NIC is not connected
to the network
•
Link indicator is green
= The NIC is connected to a valid
network link at 1000 Mbps
•
Link indicator is amber
= The NIC is connected to a valid
network link at 10/100 Mbps
•
Activity indicator is blinking green
= Network data is being
sent or received
Monitoring the Lattus A10 Access Node for Alerts
Admin alerts are informational messages about system activities you
might want to be aware of, but are not necessarily an error condition.
For example, issues related to the Distributed Data Mover feature
generate admin alerts. Admin alerts typically do not require any action
from Lattus A10 users.
The
Service > Admin Alerts
screen provides the following information:
Содержание Lattus A10
Страница 1: ...User s Guide Lattus A10 Access Node 6 68018 03 Rev A...
Страница 6: ...Contents vi Lattus A10 Access Node User s Guide...
Страница 12: ...Chapter 3 Product Overview 6 Lattus A10 Access Node User s Guide...
Страница 14: ...Chapter 4 Lattus A10 Access Node Hardware Overview 8 Lattus A10 Access Node User s Guide Rear View...
Страница 16: ...Chapter 5 Lattus A10 Access Node Licensing 10 Lattus A10 Access Node User s Guide...