DLT2000 SCSI Interface
DLT2000/DLT2700 Cartridge Tape Subsystem 8-29
PC
Type of Parameter Values
Threshold Values
Cumulative Values
Default Threshold Values
Default Cumulative Values
00b
01b
10b
11b
Figure 8-13 LOG Page Control Definitions
All types of parameter values are changeable through Log Select.
When the PC field is set to 00b or 01b and the Parameter List Length is zero, the
command is terminated with a CHECK CONDITION Status, with Sense Key of
ILLEGAL REQUEST, and ASC of INVALID FIELD IN CDB. This is because
modification of Current Threshold Values and Current Cumulative Values is not
supported.
When the PC field is set to 10b and the Parameter List Length field is 0 then all Current
Threshold Values will be reset to the Default Threshold Values. This is equivalent to no
change as Threshold Values cannot be modified.
When the PC field is set to 11b and the Parameter List Length field is 0 then all Current
Cumulative Values will be reset to the Default Cumulative Values. This is equivalent to
clearing all log pages which can be cleared.
Parameter List Length
This field specifies the length in bytes of the LOG SELECT parameter list to be
transferred from the initiator to the target during the DATA OUT phase. A parameter
list length of zero indicates that no data is to be transferred. This condition is not
considered an error (see the description of Parameter Code Reset and Page Control
fields in this section).
Error Detection Summary in LOG SELECT CDB
The following conditions constitute errors that will be detected by the drive in relation
to the CDB. The request sense data is set to ILLEGAL REQUEST, INVALID FIELD
IN CDB.
•
If PCR bit is set to 1 and parameter list length is not zero
•
If SP bit is set 1
••••
A parameter list length that would cause a parameter within a
valid page to be truncated or otherwise incompletely initialized.
Содержание DLT 2000
Страница 18: ...Table of Contents xviii DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem...
Страница 20: ...Revision History xx DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem...
Страница 38: ...Installing and Configuring the DLT2000 Tabletop Drive 2 12 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem...
Страница 94: ...Configuring and Operating the DLT2500 Mini Library 4 30 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsytem...
Страница 120: ...Configuring and Operating the DLT2700 Mini Library 5 26 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem...
Страница 146: ...Firmware Update From Tape 7 18 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem...
Страница 286: ...DLT2000 SCSI Interface 8 140 DLT2000 DLT2700 Cartridge Tape Subsystem The medium changer does not support ST ST or DT DT...
Страница 291: ...DLT2000 SCSI Interface DLT2000 DLT2700 Cartridge Tape Subsystem 8 145...
Страница 321: ...Definition of Vendor Unique Sense Data Information B 4 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem...
Страница 327: ...Sense Key Information C 6 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem...
Страница 345: ...Index 8 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem...