500300 Rev. U
SCSI Configuration
5-15
5.2.7
WRT Parity
The WRT Parity parameter must be set to
INT
(Internal) for proper drive operation.
5.3
SCSI Error Messages and Codes
As part of the power-on sequence, the SCSI PCBA performs diagnostics on itself to
verify proper operation. If it detects a failure during these power up diagnostics, it
will display one of the error messages in Table 5-4.
ERROR DISPLAY
DEFINITION
DMA CHIP FAILURE
The DMA device on the SCSI PCBA has failed.
SCSI CHIP FAILED
The SCSI Controller device on the SCSI PCBA has failed.
BUFFER FAILURE
A memory error in the 1-megabyte buffer has been detected.
RAM FAILURE
A memory error in the RAM device has been detected.
MPU FAILURE
An error in the SCSI PCBA microprocessor device has been detected
CHECKSUM ERROR
Incorrect ROM checksum was returned.
Table 5-4 SCSI Power Up Diagnostic Error Codes