4-14
Menu Operations
500300 Rev. U
Table 4-3 Maintenance Sub-Menus and Functions
4.5.1
Using the Maintenance Menu
To enter the Maintenance menu:
1.
Place the drive offline.
2.
Press the MENU switch; the MENU indicator should illuminate.
3.
Press or until display line one indicates
MAINTENANCE
.
4.
Press ENTER. Display line one indicates
DEFAULT CONFIG
.
a.
To select this function, press ENTER (see Note 1 at the bottom of
Table 4-3.
b.
To select another function, press or until the desired function appears in
display line one, and then press ENTER. The sub-menus and available
functions are listed in Table 4-3.
5.
To return the drive to normal operation, press MENU repeatedly until the
display returns to its original standby or offline indication.
4.5.2
Default Configuration Function
The
DEFAULT CONFIG
. function resets all items in the Drive Configuration menu to
their default values. If you press ENTER, display line two will indicate
ENTER TO
RESET
. If you press ENTER again, display line two will indicate
BUSY
and the drive
will reset all Drive Configuration parameters to their factory defaults. Upon
completion, display line two will indicate
DONE
. Pressing EXIT will erase the
DONE
message and return to the
DEFAULT CONFIG
. display.
Moving W1 on the WREX PCBA from ON to OFF prevents this function from being
changed and causes the display to read
FEATURE LOCKED
.
4.5.3
Default SCSI Configuration Function
The
DEF. SCSI CONFIG
. function resets all items in the SCSI Configuration menu to
their default values. Press ENTER to enable the function, and press ENTER again
to perform the function. When complete, display line two will indicate
DONE
.
4.5.4
SCSI Enable Function
The
SCSI ENABLE
: function disables communications between the tape drive and the
optional SCSI PCBA. This is only desirable when bypassing the SCSI PCBA and
interfacing directly with the Industry Standard interface. Pressing ENTER enables
this function and displays its current state:
•
YES
- The SCSI interface is connected and in use.