background image

 4 

 

 

 

 

                       7080-163D 

 

 

 

       August 3, 2018

MT. VERNON E2-C

B. Warranty Policy

4021-645J • 08-03-17

1

Hearth & Home Technologies

LIMITED LIFETIME WARRANTY

Hearth & Home Technologies, on behalf of its hearth brands (“HHT”), extends the following warranty for HHT gas, wood, pellet and 

electric hearth appliances that are purchased from an HHT authorized dealer.

WARRANTY COVERAGE:

WARRANTY PERIOD:

distributor, whichever occurs earlier. However, the warranty shall commence no later than 24 months following the date of product 

is produced in the following table.

Parts

Labor

Gas 

Pellet

 Wood

Electric

Venting

Components Covered

X

X

Igniters, auger motors, electronic components, and 

glass

X

X

X

Factory-installed blowers

X

Molded refractory panels

X

Ignition Modules

X

Firepots, burnpots, mechanical feeders/auger 

assemblies

X

Vent Free burners, Vent Free ceramic fiber logs, 

Aluminized Burners

X

X

Castings and Baffles

6 years

3 years

X

Catalyst - limitations listed

7 years

3 years

X

X

Manifold tubes, HHT chimney and termination

10 years

1 year

X

Burners, logs and refractory

 Limited 

Lifetime

3 years

X

X

X

Firebox and heat exchanger, Grate and Stainless 

Steel Burners, FlexBurn

®

 System (engine, inner 

cover,access cover and fireback)

X

X

X

X

X

All replacement parts beyond warranty period

Warranty Period

HHT Manufactured Appliances and Venting

All parts and material except as covered by 

Conditions, Exclusions, and Limitations listed

X

X

X

2 years

3 years

1 Year

90 Days

5 years

1 year

x

X

f i r e - p a r t s . c o m

Содержание MT. VERNON E2 Series

Страница 1: ...sdiction about restrictions installation inspection and permits WARNING Please read this entire manual before use of this pellet fuel burning room heater Failure to follow these instructions could res...

Страница 2: ...urther instruction refer to owner s manual Keep viewing doors tightly closed during operation Keep viewing and ash removal doors tightly closed during operation Conforme la norme ASTM E1509 12 Std Cer...

Страница 3: ...F Filling the Hopper 11 G User Dial Control 11 H Normal Startup Sequence 11 I Fire Characteristics 11 J Fire pot Purge 12 K Ignition Cycles 12 L Restarting the Appliance 12 M Shutdown 12 N Clear Space...

Страница 4: ...mponents and glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free ceramic fiber log...

Страница 5: ...warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted for a si...

Страница 6: ...or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS WARRANTIES...

Страница 7: ...it or after the unit has alarmed out due to an empty hopper Priming while under normal operating conditions will cause the fire pot to overfill HEAT SETTING HEAT SETTING O F F HI LO HEAT SETTING HEAT...

Страница 8: ...particulate emission standards at 0 74 G HR EPA CFR subpart AAA using ASTM E2779 10 ASTM 2515 11 Method Pellet Appliance sections CSA B415 1 10 Emissions Report Number 0061PS094E EPA Certification 98...

Страница 9: ...sleeping room it is recommended that 3ft of vertical be installed prior to horizontally exiting the room and a smoke CO alarm be installed in the bedroom The size of the room must be at least 50ft pe...

Страница 10: ...r to contend with small fires In the event of a hopper fire Evacuate the house immediately Notify fire department B Non Combustible Materials Material which will not ignite and burn composed of any co...

Страница 11: ...IMPORTANT DETAIL THE TIP OF THE THERMOCOUPLE MUST BE IN CONTACT WITH THE INSIDE END OF THE THERMOCOUPLE COVER OR MISSED IGNITIONS CAN OCCUR F Filling the Hopper Open the hopper lid by lifting the han...

Страница 12: ...The smoke will stop once the fire starts 2 The convection blower will automatically turn on after your appliance has been burning for approximately 10 minutes This blower transfers heat from your app...

Страница 13: ...ns approved by the regulatory authority having jurisdiction Figure 13 1 Trim adjustment is the small dial located below the main dial control The function of the trim adjustment is to allow for variat...

Страница 14: ...14 7080 163D August 3 2018 MT VERNON E2 C P Your Pellet Appliance s General Operating Parts Ash Dump Lever Baffle Latch Firepot Baffle Dial Control Hopper Switch fire parts com...

Страница 15: ...51 528 Amber Blinks Continuously Appliance is in the shutdown sequence During shut down the blowers will shut off when the exhaust temperature has cooled Red 1X Empty Hopper Alarm This alarm is cause...

Страница 16: ...em 01 and is advanced to each following item by a single press of the NEXT button The options for each item are changed using the UP or DOWN buttons ITEM 01 CLK CLOCK FORMAT 12Hr default This displays...

Страница 17: ...e temporarily changed set temperature will return to the programmed value stored in memory when start time of the next upcoming scheduled event is reached MORN DAY EVE OR NITE While the temporary chan...

Страница 18: ...house this feature can be used to synchronize this thermostat to the others Change the temperature calibration 1 Move TEMPERATURE switch to OFF 2 Move SET switch to RUN 3 Press and hold both UP and DO...

Страница 19: ...back half by using the tabs on the top edge of the thermostat housing Figure 19 1 Figure 19 1 Figure 19 2 Full battery icon Figure 19 3 Low battery icon When installing new batteries it is recommende...

Страница 20: ...wers is from the impellers becoming dirty over time See maintenance and service section for maintaining and servicing What is the metal object with the bend in it that came inside the plastic bag It i...

Страница 21: ...his pellet heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this pellet heater in a manner inco...

Страница 22: ...ash Ash Disposal Ashes should be placed in a steel container with a tight fitting lid The container of ashes should be moved outdoors immediately and placed on a non combustible floor or on the ground...

Страница 23: ...affle also Inspect the drop tube and remove any residue build up in the drop tube Figure 23 3 c Assemble the crevice tool from the micro cleaning kit to attach to a Shop Vac Figure 23 4 d Use the crev...

Страница 24: ...ket between the glass and firebox should be inspected periodically to make sure there is a good seal If the gasket is frayed or damaged replace with a new one WARNING Risk of fire Do NOT store fuel Cl...

Страница 25: ...e a high temperature paint made specifically for heating appliances d Cleaning the flue at the end of the burn season will prevent corrosives to build up and damage the flue D Soot or Creosote Fire Aw...

Страница 26: ...e top of the latch up to lock latch into place G Glass Replacement 1 Swing open the face and remove the door from the appliance by lifting the door off of the hinge pins and lay on a flat surface face...

Страница 27: ...als to the new blower 10 Reposition and Re secure the back panel NOTE Make sure wires are connected prior to restarting the appliance Failure to do so will result in the side mounted safety thermal sn...

Страница 28: ...eck hopper switch wires for integrity Safety snap disc is tripped 3 Check to make sure convection blower wires are connected and reset snap disc located on RH side of appliance Clean inspect convectio...

Страница 29: ...probe to exhaust blower housing keeping its wire away from hot surfaces Control board is defective Replace control board Convection Blower fails to shut off Wire short between blower and ground Contro...

Страница 30: ...over the fire pot and or excessive flame Dirty Appliance Clean unit including the fire pot exhaust path and venting system Feed Motor locked on Follow corrective action for feed motor not turning off...

Страница 31: ...end to control board Failed component Replace exhaust probe securing it to exhaust blower housing keeping wire away from hot surfaces 4 Red Flashes Missed Ignition Hopper empty Fill the hopper Feed m...

Страница 32: ...designed to pull the exhaust from the appliance and push it out through the venting system 2 Control Board The control board is located on the right side of appliance It controls the functioning of t...

Страница 33: ...August 3 2018 7080 163D 33 MT VERNON E2 C Date of Service Performed By Description of Service B Service and Maintenance Log fire parts com...

Страница 34: ...34 7080 163D August 3 2018 MT VERNON E2 C C Exploded Drawings fire parts com...

Страница 35: ...August 3 2018 7080 163D 35 MT VERNON E2 C D Parts List fire parts com...

Страница 36: ...36 7080 163D August 3 2018 MT VERNON E2 C fire parts com...

Страница 37: ...August 3 2018 7080 163D 37 MT VERNON E2 C fire parts com...

Страница 38: ...38 7080 163D August 3 2018 MT VERNON E2 C fire parts com...

Страница 39: ...August 3 2018 7080 163D 39 MT VERNON E2 C fire parts com...

Страница 40: ...ed installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dealership p...

Отзывы: