![Quadra-Fire MT. VERNON E2 Series Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/quadra-fire/mt-vernon-e2-series/mt-vernon-e2-series_owners-manual_3480611008.webp)
8
7080-163D
August 3, 2018
MT. VERNON E2-C
Model
Mt. Vernon Pellet Stove E2
Laboratory
OMNI Test Laboratories, Inc.
Report No.
061-S-83-2
Type
Solid Fuel Room Heater, Pellet Fuel
Burning Type
Standard
ASTM E1509-12, ULC S627-00 and
(UM) 84-HUD, Mobile Home Approved.
FCC
Complies with Part 15 of FCC Rules.
Operation is subject to the following two
conditions: (1) this device may not cause
harmful interference, and (2) this device
must accept any interference received,
including interference that may cause
undesired operation.
This pellet appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate
this pellet appliance in a manner inconsistent with the operating instructions in the owner’s manual.
The Quadra-Fire Mt. Vernon E2 Pellet Appliance meets the U.S. ENVIRONMENTAL PROTECTION AGENCY Certified
to comply with 2020 particulate emission standards at 0.74 G/HR EPA CFR subpart AAA, using ASTM E2779-10, ASTM
2515-11 Method- Pellet Appliance sections, CSA B415.1-10.
Emissions Report
Number:
0061PS094E
EPA Certification #:
98-17
EPA Certified Emissions:
0.74 g/hr
*LHV Tested Efficiency:
83.2%
**HHV Tested Efficiency:
77.9%
***EPA BTU Output:
12,682 - 39,428 / HR
****BTU Input:
16,396 - 50,775 / HR
Vent Size:
3 or 4, “L” or “PL”
Hopper Capacity:
80 lbs.
Fuel
Wood Pellets
* Weighted average LHV efficiency using data collected
during EPA emissions test.
**
Weighted average HHV efficiency using data collected
during EPA emissions test.
***
A range of BTU outputs based on HHV and the burn
rates from the low and high EPA tests.
****
Based on the maximum feed rate per hour multiplied
by approximately 8600 BTU’s which is the average BTU’s
from a pound of pellets.
1
Listing and Code Approvals
A. Appliance Certification
NOTICE:
This installation must conform with local codes. In the absence of local codes you must comply with the
ASTM
E1059-12, ULC S627-00, (UM) 84-HUD and ULC/ORD-C-1482.
B. BTU & Efficiency Specifications
f i r e - p a r t s . c o m
Содержание MT. VERNON E2 Series
Страница 34: ...34 7080 163D August 3 2018 MT VERNON E2 C C Exploded Drawings fire parts com...
Страница 35: ...August 3 2018 7080 163D 35 MT VERNON E2 C D Parts List fire parts com...
Страница 36: ...36 7080 163D August 3 2018 MT VERNON E2 C fire parts com...
Страница 37: ...August 3 2018 7080 163D 37 MT VERNON E2 C fire parts com...
Страница 38: ...38 7080 163D August 3 2018 MT VERNON E2 C fire parts com...
Страница 39: ...August 3 2018 7080 163D 39 MT VERNON E2 C fire parts com...