23
3-90-7003999
Quadra-Fire • Hudson Bay Installation Manual_R26 • 01/20
A. Fuel Conversions
Before making gas connections ensure that the appliance
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to
meet the appliance and locality needs must be made by
a qualified technician using Hearth & Home Technologies
specified and approved parts.
1. Converting to LP Gas
KIT CONTENTS:
Replacement orifice; replacement pilot
injector; and valve regulator.
TOOLS REQUIRED:
Ratchet with 7/16 in. socket and 2 in.
- 4 in. extension: power drill (a 90° handle is helpful); #2
Phillips bit; 5/32 in. allen wrench; 5/8 in. open end wrench.
Figure 6.2
-
Lift burner up and out of the firebox opening.
Figure 6.4
-
Slide the burner support to the left to access the
orifice.
Burner support
screws locations
NOTE: Gas conversions should only be performed
by a qualified service person, and/or where required
by state and local codes, licensed installer/service
technician. In the Commonwealth of Massachusetts,
installation must be performed by a licensed
plumber or gas fitter.
6
6
Gas Information
3 screws
Figure 6.3 -
Remove the three screws on the front of the burner
support. Set screws aside.
Figure 6.1
-
Remove right and left twigs and right and left rear logs
from the burner pan, if installed. Remove the 2 nuts that secure
the burner pan to the burner support with the ratchet and socket.
2 nuts holding
burner pan