Grand Bay 40 Gas Freestanding
Page 25
January 2000
January 2000
M
A
IN
T
E
N
A
N
C
E
MAINTENANCE
CLEANING AND INSPECTION
At least once yearly, preferably before the heating season, have the insert and venting system
cleaned and inspected by a qualified service person. This will insure proper and safe operation
throughout the year.
CLEANING THE BURNER TUBES
1. Turn off pilot light.
2. Open door.
3. Remove logs and glowing charcoals.
4. Vacuum burner compartment, especially around orifice and
primary air openings.
5. Relight pilot. Check to insure flames are touching
millivolt generator (see diagram at right).
6. Reinstall logs. See page 14 for log installation instructions.
7.
Close and latch door.
8. Recheck pilot and main burner to insure they are operating correctly.
GLASS CLEANING
WARNING: DO NOT CLEAN GLASS WHEN HOT.
1. Turn off pilot.
2. Open door.
WARNING:
DO NOT USE ABRASIVE CLEANERS ON GLASS OR GOLD SURFACES.
3. Using regular glass cleaner, spray the glass surface and wipe with soft cloth or clean paper
towel until surface is dry.
4. Close and latch door.
5. Relight pilot and check main burner’s operation.
NOTE:
If you observe a white film on the door glass, use a hard water deposit glass cleaner
or contact your dealer.
NOTE: Do not use abrasive materials or chemical cleaners.
WARNING: Running the appliance on high for extended periods without the use of
the blower can cause the appliance to overheat, resulting in tarnishing or discoloring
of the gold plating on the door. We recommended that you operate the appliance
at lower valve control settings, or cycle the appliance on and off for short periods
when the blower is not in use.