SPECIFICATIONS
NATURAL GAS PROPANE
Manifold pressure 3.5” WC 10.0” WC
Minimum inlet gas supply pressure 4.5” WC 11 0” WC
Maximum inlet gas supply pressure 7.0” WC 14.0” WC
BTU input rating (high) 40,000 40,000
BTU input rating (low) 28,000 28,000
Efficiency with fan (steady state) 81.4% 83%
Efficiency without fan (steady state) 81% 81%
A.F.U.E. 66% 68%
GAS LINE CONNECTION
Gas line connection can be made near the lower rear of the appliance (3/8” gas hookup). You must supply
a shutoff valve installed in a visible location within three feet (3’) of the stove.
CAUTION
In some areas, gas line pressure may be more than 1/2 psig (14” wc). If you believe that this might
be the case in your locality, contact your gas supplier or local utility company. Line pressure
greater than 1/2 psig will damage the appliance valve. You must install a regulator upstream from the
appliance if line pressure is greater than 1/2 psig.
PRESSURE TESTING
During any pressure testing of the gas supply piping system that exceeds test pressures of 1/2 PSIG, this
appliance and its individual shutoff valve must be disconnected from the piping system. If test pressure is
less than or equal to 1/2 PSIG, then this appliance must be isolated from the piping system by closing its
individual shutoff valve. The gas valve is supplied with pressure test ports for checking input and output
pressures. These are located just next to the on/off knob and can be found inside the hinged lower access
grill. The port on the left is for output pressure and the port on the right for input. Pressure can be checked
by turning the captured screw counterclockwise two or three turns and then placing the manometer tubing
over the test port. BE SURE TO CLOSE CAPTURED SCREWS AFTER TESTING BY TURNING
THEM CLOCKWISE. DO NOT OVERTIGHTEN SCREWS.
NOTE: To make flame and heat output adjustments, turn the HI-LO knob located on the center of the valve
(as seen below). Turn clockwise for a higher flame and counterclockwise for a lower flame.
LISTINGS
The Quadra-Fire GB40 FS is listed to ANSI Z21.11.1 and CAN 1-2.1 by OMNI-Test Laboratories, Inc.
OUTPUT SIDE
TEST VALVE
INPUT SIDE
TEST VALVE