Grand Bay 40 Gas Freestanding
Page 31
January 2000
January 2000
6. Disconnect thermocouple, thermopile
and piezo wire connector from existing
pilot assembly.
See Figure D
7. Align old pilot line side by side with new
line and pre-bend new line into correct
position.
See Figure E
8. Insert new pilot line into new pilot
assembly and tighten fitting with 10mm
wrench.
See Figure F
9. Insert new lox-it fitting into valve and
hand tighten.
See Figures G & H
CONVERSION INSTRUCTIONS, CONT.
Fig. D
Fig. E
Fig. F
Fig. G
Lox-it fitting
Fig. H
Lox-it fitting in valve.
C
O
N
V
E
R
S
IO
N
OLD
NEW