5
250-3692 (11/2000) DVi32 Gas Insert
SPECIFICATIONS
NG
LP
Manifold pressure
3.5” WC
10.0” WC
Minimum inlet gas supply pressure
4.5” WC
11 0” WC
Maximum inlet gas supply pressure
7.0” WC
14.0” WC
BTU input rating (high)
32,000
32,000
BTU output rating (high)*
26,800
27,808
BTU input rating (low)
20,000
25,000
BTU output rating (low)*
16,800
21,725
Minimum efficiency*
78.8%
82.9%
Maximum efficiency**
84.0%
86.9%
*Minimum vent, blower off
**Maximum vent, blower on
GAS LINE CONNECTION
Gas line connection can be made behind the left side fascia of the appliance (3/8” gas hookup) or through gas
supply access door behind left-hand side fascia. You must supply a shutoff valve installed in a visible location
within 3’ (914mm) of the stove, or on left-hand side fascia access door.
CAUTION
IN SOME AREAS, GAS LINE PRESSURE MAY BE MORE THAN 1/2 PSIG (14” WC). IF YOU BELIEVE THAT
THIS MIGHT BE THE CASE IN YOUR LOCALITY, CONTACT YOUR GAS SUPPLIER OR LOCAL UTILITY
COMPANY. LINE PRESSURE GREATER THAN 1/2 PSIG WILL DAMAGE THE APPLIANCE VALVE. YOU MUST
INSTALL A REGULATOR UPSTREAM FROM THE APPLIANCE IF LINE PRESSURE IS GREATER THAN 1/2
PSIG.
OUTPUT
SIDE TEST
PRESSURE
INPUT
SIDE TEST
PRESSURE
PRESSURE TESTING
If the gas supply piping system exceeds pressures of 1/2 PSIG during
testing, this appliance and its individual shutoff valve must be
disconnected from the piping system. If test pressure is less than or
equal to 1/2 PSIG, then this appliance must be isolated from the piping
system by closing its individual shutoff valve. The gas valve is supplied
with pressure test ports for checking input and output pressures. These
are located just above the on/off knob and can be found inside the left-
hand side fascia access door. The port on the bottom is for output
pressure and the port on the top for input. Pressure can be checked by
turning the captured screw counterclockwise two or three turns and
then placing the manometer tubing over the test port. BE SURE TO
CLOSE CAPTURED SCREWS AFTER TESTING BY TURNING THEM
CLOCKWISE. DO NOT OVERTIGHTEN SCREWS.
NOTE
: To make flame and heat output adjustments, turn the HI-LO
knob located on the center of the valve (as seen in diagram at right).
Turn counterclockwise for a higher flame and clockwise for a lower
flame.