250-3692 (11/2000)  DVi32 Gas Insert

TROUBLESHOOTING

A.

Pilot won’t light
1.

Make sure valve setting is in the pilot position.

2.

Check for spark at igniter.
a.

If no spark:
1.

Check the wiring between the piezo and
the igniter. If bad, fix wiring; if good, you
may have a faulty piezo or cracked ceramic
on the electrode.

2.

Call your Quadra-Fire dealer.

b.

If there is a spark:
1.

Try to light the pilot with a match. The flame
should either light or flutter.
a.

If the flame flutters but does not light the
pilot, there probably is air in the line. Hold
flame to pilot hood, then bleed the line
until gas comes through.

b.

If the match flame does not flutter, make
sure the gas is turned on and be sure
you are pushing the knob in all the way.
If this still doesn’t help, you may be
dealing with a bad valve, a blocked pilot
orifice, or a kinked pilot line.

3. Call your dealer or authorized service person.

B.

Pilot goes out when knob is released
1.

Wait five minutes and try again. If the pilot still goes
out, try again and hold the knob in longer.

2.

If the problem persists, call your dealer or authorized
service person.

C.

Pilot lights but burner won’t ignite
1.

Make sure the knob is turned to the “on” position.

2.

Turn the thermostat up.

3.

If there is no thermostat, flip the manual switch on the
right side panel of the insert. If the burner does not
light, short out the thermostat screws on the face of
valve marked TH and TPTH. If the burner lights, you
may have a problem in the wiring of the stove, and it
should be checked.

4.

Check the thermostat and thermopile connections at
the valve, and tighten or reconnect if needed.

5.

If the burner still will not ignite, you may have a bad
valve; call your dealer or authorized service person.

Check the pilot and burner flames periodically. When properly
adjusted, they should look like the flames in the illustration below.
Call your dealer or authorized service person to have the pilot
properly adjusted.

Pilot Hood

Flame

Millivolt
Generator

Flame

Thermocouple

Pilot assembly showing flame properly adjusted.

ACCESSORIES

These may be ordered through your Quadra-Fire dealer.

812-2880 Thermostat, manual
811-0520 Thermostat, electronic set back
841-0320 Remote control
841-0620 Zero clearance fireplace box
842-2571 Gold fascia
842-2561 Black fascia
842-2590 Gold door crown, arched
842-2610 Gold door crown, rectangle
842-2580 Black door crown, arched
842-2600 Black door crown, rectangle
841-0561 Panel and trim, arched, standard
841-0571 Panel and trim, arched, OTS
841-0581 Panel and trim, standard
841-0591 Panel and trim, OTS
841-0601 Panel, inside fit, standard

841-0611 Panel, inside fit, OTS

SERVICE PARTS

842-2630 Baffle
842-2860 Blower, 170 cfm
842-0380 Blower cord, 6 foot
842-2750 Brick, Front Piece
842-2760 Brick Set
842-0250 Millivolt generator (thermopile)
842-0390 Thermocouple
842-1660 Rocker switch, high temperature
842-2620 Owner’s manual
842-0360 Piezo igniter
842-2700 Log set
842-2670 Door glass
842-2660 Wire harness
842-0370 Speed control with knob
832-2970 Blower snap disc, ceramic, 125 degree
842-2650 LP conversion kit

842-2640 NG conversion kit

ZERO CLEARANCE FIREPLACE KIT

f i r e - p a r t s . c o m

Содержание DVI-32

Страница 1: ...epartment Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas suppli...

Страница 2: ...rocedures 9 Front brick shutoff plate adjustment 9 Gas connections 9 Venting instructions 10 Installation precautions 10 Safety precautions 10 Venting parts list 11 Venting system maintenance 11 Planning your installation 12 Vertical terminations Using GS series pipe 12 Installing into an existing masonry or factory built metal chimney 15 Lighting instructions 17 First fire 18 Maintenance Cleaning...

Страница 3: ...N 1 149 This vented gas fireplace is not for use with air filters Install and use only in accordance with manufactaurer s installation and operating instructions Not for use with solid fuel Keep burner and control compartment clean See installation and operating instructions accom panying this appliance Due to high surface temperatures keep children clothing and furniture away ELECTRICAL SUPPLY 12...

Страница 4: ...le materials gasoline and other flammable vapors and liquids This appliance is hot during operation and should be located out of heavy traffic areas and away from furniture and draperies Clothing or other flammable material should not be placed on or near the appliance Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ...

Страница 5: ... A REGULATOR UPSTREAM FROM THE APPLIANCE IF LINE PRESSURE IS GREATER THAN 1 2 PSIG OUTPUT SIDE TEST PRESSURE INPUT SIDE TEST PRESSURE PRESSURE TESTING If the gas supply piping system exceeds pressures of 1 2 PSIG during testing this appliance and its individual shutoff valve must be disconnected from the piping system If test pressure is less than or equal to 1 2 PSIG then this appliance must be i...

Страница 6: ...6 250 3692 11 2000 DVi32 Gas Insert DIMENSIONS 7 1 2 190mm 23 15 16 680mm 12 305mm 29 737mm 30 762mm 30 762mm 14 1 2 368mm 13 13 16 351mm 10 9 16 268mm 11 16 18mm fire parts com ...

Страница 7: ...000 over the 2000 level Exception As permitted by the authority having jurisdiction LISTINGS The Quadra Fire DVI 32 is listed to ANSI Z21 88a 1998 CSA 22 33a M98 and CAN1 2 17 M91NFPA 70 by OMNI Test Laboratories Inc Beaverton Oregon CLEARANCES TO COMBUSTIBLES Minimum clearances to combustible materials from stove body A Side wall to combustibles 9 229mm B Height of combustible above bottom of ins...

Страница 8: ...Place nuggets in a single layer across the burner tube Make sure that nuggets do not fall behind the tube If more than one layer of nuggets is placed across the burner tube flame impingement and tall sooty flames can result If the flames on one side are too high adjust the nuggets until the flame is the same height on both sides of the stove The log set is installed at the factory To remove log se...

Страница 9: ... 2m 20 gauge 25 7 6m 22 gauge 18 5 5m WARNING Do not cut the grounding terminal off under any circumstances Do not route the power cord under the body of the appliance due to high temperatures INSTALLATION PROCEDURES The following procedures show some of the basic installation applications Remember that every installation is different and the installer should adjust to insure that the appliance is...

Страница 10: ...ing system installation of any component part not approved by Aladdin Hearth Products or installation other than as instructed by these instructions Consult your local building codes before beginning this installation WARNING Always maintain the required clearances air space to nearby combustibles to avoid creating a fire hazard Do not fill air space with insulation Minimum clearance between vent ...

Страница 11: ... 12 12 roof itch 945 45 elbow two maximum 953 Storm collar 963 Ceiling firestop 988 Wall strap 991 High wind termination cap 2280 3 76mm chimney flex liner 923GCL Co linear to co axial adaptor VENTING SYSTEM MAINTENANCE Conduct an inspection of the venting system semiannually Recommended areas to inspect are as follows 1 Check areas of the venting system which are exposed to the elements for corro...

Страница 12: ...ero clearance chimney it is important to carefully measure the length of flex needed to reach from the appliance outlet to the termination cap If the flex length is too short a flex coupler will be needed to attach an additional length of flex liner to make up the difference If the flex length is too long the liner could sag below the appliance outlet which could result in a potential fire hazard ...

Страница 13: ...tep 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance up through the round support box Insure that all pipe and elbow connections are in their fully twist locked position Step 5 Cut a hole in the roof centered on the small drill hole placed in the roof in step 2 The hole should be of sufficient size to meet the minimum requirements for clearance to combu...

Страница 14: ...roofing nails Insure the roofing material overlaps the top edge of the flashing Figure 4 Verify that you have at least the minimum clearance to combustibles at the roofline Step 7 Continue to assemble pipe sections and seal with silicone until the height of the vent cap H Figure 5 meets the minimum building code requirements described in Table 1 Figure 5 and outlined in the current CANGA Bl49 Inst...

Страница 15: ...rope through the end of the flex puller and tie a knot at the end of the rope Attach the flex puller to the flex liner using four sheet metal screws Be sure to label one liner exhaust and other intake Carefully feed the liner down the chimney and out through the damper NOTE If additional lengths of flex liner are needed to span the chimney height use a flex coupler to connect the pieces of flex li...

Страница 16: ...ap SDV part 991 to the top adaptor see Figure 9 Do not use any other termination cap Step 9 Attach the flex lines to the appliance using hose clamps provided FIG 7 FIG 8 FIG 9 We strongly recommend the use of two flex liners to properly install the DVi 32 NOTE THE FOLLOWING INSTALLATION IS APPROVED FOR APPLICATIONS IN THE UNITED STATES ONLY IT IS NOT APPROVED FOR INSTALLATIONS IN CANADA The DVI 32...

Страница 17: ...the left hand side fascia access door to expose the gas control 5 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 6 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you smell gas STOP Follow B of the safety information above If you don t smell gas go to the next...

Страница 18: ...an odor and steam coming from the insert This is normal it is the high temperature paint finishing the curing process Open the door and or windows in the home or structure for ventilation We recommend that you cycle the insert to heat for several minutes until it reaches the curing stage and then turn to off to cool for five minutes Then turn the insert back on and burn until the steam and or odor...

Страница 19: ...ing of the stove and it should be checked 4 Check the thermostat and thermopile connections at the valve and tighten or reconnect if needed 5 If the burner still will not ignite you may have a bad valve call your dealer or authorized service person Check the pilot and burner flames periodically When properly adjusted they should look like the flames in the illustration below Call your dealer or au...

Страница 20: ...ch as but not limited to blowers wiring thermodisc switches and gas valves are covered by Aladdin s one year warranty program Aladdin Hearth Products will not be responsible for any alteration to the unit which causes sooting that results in damage to the interior of the building in which this appliance is installed This warranty is void if the stove has been operated in atmospheres contaminated b...

Отзывы: