18
250-3692 (11/2000) DVi32 Gas Insert
FIRST FIRE
NOTE:
Never operate this appliance with the door open.
NOTE:
No electrical power supply is required for the gas
control to operate. Standing pilot allows the valve
to operate with manual switch or millivolt
thermostat.
WARNING:
WHEN THE APPLIANCE IS EQUIPPED
WITH A 24 KARAT GOLD-PLATED DOOR, YOU MUST
CLEAN ALL THE FINGERPRINTS AND OILS FROM THE
GOLD SURFACE BEFORE FIRING THE APPLIANCE
FOR THE FIRST TIME. USE A GLASS CLEANER OR
VINEGAR AND A TOWEL TO INSURE THAT THE OIL IS
REMOVED. IF NOT CLEANED PROPERLY BEFORE
FIRING, FINGERPRINTS OR OIL CAN CAUSE
PERMANENT MARKINGS ON THE GOLD PLATING.
AFTER THE GOLD PLATING IS CURED, THE OILS WILL
NOT AFFECT THE FINISH AND LITTLE MAINTENANCE
IS REQUIRED; JUST WIPE CLEAN AS NEEDED.
Before first firing the insert, read this owner’s manual to be
familiar with the stove’s features, controls, and cautions for
operation.
Remove all labels from glass before operating this insert
for the first time.
Plug power cord into a properly installed outlet for blower
operation.
The blower system has an on/off thermo snap disc that will
turn the blower on automatically when the proper
temperature is reached, and will turn the blower off when it
cools down in order not to blow cool air after shut down.
The rheostat to control the blower speed is located on the
right side of the appliance, behind the fascia.
Manual on/off switch for control valve is located on the right
side of the applaince, behind the fascia.
Follow the lighting instructions on page 17 of this manual,
or metal lighting instructions located behind gas supply
access panel behind left side fascia.
During your first fire in the appliance, you may notice an
odor and steam coming from the insert. This is normal; it is
the high temperature paint finishing the curing process.
Open the door and/or windows in the home or structure for
ventilation.
We recommend that you cycle the insert to heat for several
minutes until it reaches the curing stage, and then turn to
off to cool for five minutes. Then turn the insert back on,
and burn until the steam and/or odor no longer appears.
If odor persists, turn off the gas supply to the insert, and call
your local dealer or authorized service person to inspect
the appliance.
MAINTENANCE
CLEANING AND INSPECTION
At least once yearly, preferably before the heating season,
have the insert and venting system cleaned and inspected
by a qualified service person. This will insure proper and
safe operation throughout the year.
CLEANING THE BURNER TUBES
1.
Turn off pilot light.
2.
Open door by turning eye bolt and releasing door.
3.
Remove log set (see page 8).
4.
Vacuum burner compartment, especially around orifice
and
primary air openings.
5.
Relight pilot. Check to insure flames are touching milli-
volt generator
(see diagram at right).
6.
Reinstall log set.
7.
Close front door and lock it in place.
8.
Recheck pilot and main burner to insure they are oper-
ating correctly.
GLASS CLEANING
WARNING: DO NOT CLEAN GLASS WHEN HOT.
1.
Turn off pilot.
2.
Open door by turning bolt.
WARNING: DO NOT USE ABRASIVE CLEAN-
ERS ON GLASS OR GOLD SURFACES.
3.
Using regular glass cleaner, spray the glass surface
and wipe with soft cloth or clean paper towel until sur-
face is dry.
4.
Close door and tighten bolt to prevent opening of the
door while in operation.
5.
Relight pilot and check main burner’s operation.
NOTE:
If you observe a white film on the door glass, use a
hard water deposit glass cleaner or contact your dealer.
NOTE: Do not use abrasive materials or chemical clean-
ers.
Pilot Hood
Flame
Millivolt
Generator
Flame
Thermocouple
f i r e - p a r t s . c o m