CB1200-I PELLET STOVE SERVICE MANUAL
CB1200-I PELLET STOVE SERVICE MANUAL
I. UNIT FAILS TO SHUT OFF
1) CHECK THERMOSTAT AND THERMOSTAT WIRE
2) CHECK THE JUNCTION BOX & WIRE HARNESS
3) CHECK THE CONTROL BOX
TROUBLE SHOOTING & REPAIR
J. CONVECTION BLOWER KEEPS RUNNING OR FAILS TO START
1) CHECK #1 SNAP DISC
2) CHECK CONVECTION BLOWER
3) CHECK FOR VOLTAGE TO THE #1 SNAP DISC
K. STOVE CYCLES ON AND OFF -- THERMOSTAT ALWAYS ON
1) CHECK #1 SNAP DISC (CONVECTION BLOWER)
2) IF #1 SNAP DISC FAILS THEN #2 SNAP DISC WILL TRIP
*AFTER THE #2 SNAP DISC COOLS DOWN IT WILL TURN THE
THERMOSTAT BACK ON (CALL LIGHT)
3) CHECK WIRING FOR LOOSE CONNECTIONS
L. LARGE FIRE, ASH BUILD UP & DIRTY GLASS
1) CHECK FIREPOT, MAY NEED TO BE CLEANED
2) CLEAN EXHAUST AND HEAT EXCHANGER SYSTEM
3) ADJUST FEED ADJUSTMENT PLATE IN THE HOPPER
4) CHECK CONTROL BOX FEED TIMES
*HIGH ------- (7.5 SECOND ON TIME)
*MEDIUM -- (6 SECOND ON TIME)
*LOW --------(4.7 SECOND ON TIME)
M. STOVE IGNITES -- GOES OUT -- CALL LIGHT STILL ON
“ STOVE IS INCONSISTANT IN OPERATION “
1) INSPECT THERMOCOUPLE AND ITS POSITION OVER THE POT
2) CHECK THE FEED MOTOR
3) ADJUST FEED ADJUSTMENT PLATE FOR A LARGER FIRE
4) CHECK THE EXHAUST AND HEAT EXCHANGER SYSTEM
5) CHECK THE VACUUM SWITCH
7-31-2002 PAGE 5 250-7700