THERMOSTAT CIRCUIT TROUBLE-SHOOTING
JUNCTION BOX
THERMOSTAT CIRCUIT
YELLOW
ACCY
JUMPER
1
3
4
5
6
2
RESET BUTTON
CALL LIGHT
THERMOSTAT BLOCK
#2 SNAP DISC
YELLOW
YELLOW
YELLOW
YELLOW
YE
LL
O
W
7-31-2002 PAGE 16 250-7700
1) UNPLUG THE STOVE & REMOVE THE CONTROL BOX.
2) TURN ON THE THERMOSTAT & MAKE SURE THE ACCESSORY JUMPER IS IN PLACE.
3) CHECK FOR CONTINUITY AT PIN 7 & PIN 9 ON THE JUNCTION BOX.
IF THE CIRCUIT HAS CONTINUITY: REPLACE THE CONTROL BOX
IF NO CONTINUITY, CONTINUE TO THE NEXT STEP
4) INSTALL A JUMPER WIRE ON THE THERMOSTAT & CHECK FOR CONTINUITY AT PIN 7 & PIN 9
IF THE CIRCUIT HAS CONTINUITY: REPLACE THE THERMOSTAT
IF NO CONTINUITY, CONTINUE TO THE NEXT STEP
5) REMOVE THE THERMOSTAT WIRES FROM THE THERMOSTAT BLOCK & INSTALL A JUMPER WIRE.
IF THE CIRCUIT HAS CONTINUITY: REPLACE THE THERMOSTAT WIRE
IF NO CONTINIUTY, CONTINUE TO THE NEXT STEP
6) INSTALL A JUMPER WIRE ON THE T-STAT BLOCK & #2 SNAP DISC. CHECK CONTINUITY AT PIN 7&9
.
IF THE CIRCUIT HAS CONTINUITY: REPLACE THE #2 SNAP DISC
IF NO CONTINUITY, CONTINUE TO THE NEXT STEP
7) INSTALL A JUMPER WIRE ON THE T-STAT BLOCK & THE RESET BUTTON. CHECK CONTINUITY. (7&9)
IF THE CIRCUIT HAS CONTINUITY: REPLACE THE RESET BUTTON
IF NO CONTINUITY: REPLACE THE JUNCTION BOX