CONVECTION BLOWER TESTING
7-31-2002 PAGE 13 250-7700
USING THE TEST BOX:
USING THE COMPONENT TEST CORD:
TEST BOX (AS IT IS INSTALLED IN THE STOVE)
1) UNPLUG THE STOVE, REMOVE THE CONTROL BOX AND INSTALL THE TEST BOX.
2) INSTALL A JUMPER WIRE ON THE #1 SNAP DISC (PURPLE WIRES) AND THEN PLUG THE STOVE IN.
3) TURN ON THE CONVECTION BLOWER SWITCH.
A. IF BLOWER COMES ON: REPLACE #1 SNAP DISC OR THE CONTROL BOX
B. IF BLOWER DOESN’T COME ON: CHECK WIRE HARNESS OR REPLACE BLOWER
1) UNPLUG THE CONVECTION BLOWER FROM THE WIRE HARNESS.
2) INSTALL THE FEED MOTOR ADAPTER WIRE TO THE TEST CORD.
3) PLUG IN THE TEST CORD TO THE CONVECTION BLOWER AND TURN THE SWITCH ON.
NOTE: THIS WILL ONLY TEST THE HIGH SPEED CIRCUIT OF THE BLOWER.
CONVECTION BLOWER
SWITCH
SNAP DISC #1
JUMPER WIRE
TEST CORD w/ ADAPTER
TEST CORD CONNECTED TO THE BLOWER