background image

5

April 23, 2019

7021-801B

CASTILE FREESTANDING

Getting Started

Recommended 

Location

Marginal

Location

Location

Not

Recommended

 

Recommended

Location

 

Location NOT 

Recommended

Multi-level Roofs

Windward

Leeward

Outside Air Kit Termination Cap

Figure 5.1

Install Guide

A. Design, Installation & Location Considerations 

1.  Appliance Location

Since pellet exhaust can contain ash, soot or sparks, you 

must consider the location of:

•  Windows

•  Air Intakes

•  Air Conditioner

• 

Overhang, soffits, porch roofs, adjacent walls

• 

Landscaping, vegetation

•  Horizontal or vertical vent termination

2.  Floor Support

The supporting floor under the appliance must be able to 

handle the weight of the appliance, fuel load and the weight 

of the chimney.

Ensure that your floor will support these weights prior to 

installation. Add sufficient additional support to meet this 

weight requirement prior to installation. The weight of the 

appliance is 208 lbs.

NOTICE:

 Check building codes prior to installation.

•  Installation MUST comply with local, regional, state and 

national codes and regulations.

•  Consult insurance carrier, local building inspector, 

fire officials or authorities having jurisdiction over 

restrictions, installation inspection and permits.

It is a good idea to plan your installation on paper, using 

exact measurements for clearances and floor protection, 

before actually beginning the installation. Location of the 

appliance and chimney will affect performance.

Consideration must be given to:

• 

Safety, convenience, traffic flow

• 

Placement of the chimney and chimney connector and 

to minimize the use of chimney offsets.

• 

Place the appliance where there will be a clear 

passage for a Listed chimney through the ceiling and 

roof (vertical) or through exterior wall (horizontal).

•  Installing the required outside air kit will affect the 

location of the vent termination.

When locating vent and venting termination, the ideal 

location is to vent above roof line when possible. This 

minimizes the affects of wind loading.

WARNING

Risk of Fire.

Damaged parts could impair safe operation. Do NOT 

install damaged, incomplete or substitute components.

Содержание CASTILE-MBK-C

Страница 1: ...not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other applia...

Страница 2: ...mostat Wall Control Location 6 C Tools And Supplies Needed 6 D Inspect Appliance and Components 6 E Install Checklist 7 3 Dimensions and Clearances 8 A Appliance Dimensions 8 B Clearances to Combustib...

Страница 3: ...proper operation It is against federal regulations to operate this pellet appliance in a manner inconsistent with operating instructions in this manual Emissions Report Number 0061PM077E EPA Certific...

Страница 4: ...on of such fuels can expose you to chemicals including carbon black which is known to the State of California to cause cancer and carbon monoxide which is known to the State of California to cause bir...

Страница 5: ...ior to installation Installation MUST comply with local regional state and national codes and regulations Consult insurance carrier local building inspector fire officials or authorities having jurisd...

Страница 6: ...lation to ensure maximum safety and benefit Follow pipe manufacturer instructions for installation and air clearance requirements C Tools And Supplies Needed Tools and building supplies normally requi...

Страница 7: ...tion and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installation is complete Electrical 120 VAC unswitched power provided to the ap...

Страница 8: ...ure 8 1 Top View Figure 8 2 Top View with TPVNT 2 and 812 3570 Figure 8 4 Top view with TPVNT 2 and 811 0720 11 7 8 in 302mm 11 7 8 in 302mm 5 3 4 in 146mm 3 1 2 in 89mm 5 in 127mm 11 7 8 in 297mm 3 i...

Страница 9: ...de View Figure 9 4 Side View with TPVNT 2 and 811 0720 28 1 2 in 724mm 24 in 610mm 23 5 8 in 600mm 15 1 2 in 394mm 9 1 2 in 241mm 28 5 8 in 727mm 27 in 686mm 24 1 2 in 622mm 22 7 8 in 581mm 22 7 8 in...

Страница 10: ...vidual design preference C C A B D E F G G H H Horizontal Through the Wall Inches Millimeters A Back Wall to Appliance 2 51 B Side Wall to Appliance 6 152 Corner Installation Inches Millimeters C Wall...

Страница 11: ...de of pipe shaded area to the wall thimble 152MM USA INSTALLATIONS A non combustible floor protection is recommended extending beneath the flue pipe when installed with horizontal venting or under the...

Страница 12: ...ight 43 1092 n a n a B Width 38 965 n a n a C Depth n a n a 36 914 D To Side Wall 6 152 n a n a All minimums listed are to a combustible surface NOTE Illustrations reflect typical installations and ar...

Страница 13: ...nd protruding parts of the structure P 12 in Clearance above roof line for vertical terminations All minimum clearances are listed with an Outside Air Kit OAK installed unless otherwise noted in table...

Страница 14: ...t of the demands of the pellet appliance but consideration must be given to the total house demand House demand may consume the air needed for the appliance It may be necessary to add additional venti...

Страница 15: ...through the chimney Install through the warm airspace enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Considerations for successf...

Страница 16: ...until you reach your altitude above sea level 3 If you fall below the diagonal line 3 or 4 inch 76 to 102mm pipe may be used 4 If it is anywhere above the diagonal line a 4 inch 102mm diameter pipe i...

Страница 17: ...ed for mobile home installations Must use 3 or 4 inch 76 102mm L or PL Listed pellet venting or Listed double wall pipe and a Quadra Fire Outside Air Kit in mobile homes NOTE In Canada where passage t...

Страница 18: ...ean out Cover 24 in 610mm Minimum Ceiling Support 6 in 152mm Flue Connector 6 in 152mm Class A Chimney Connector Adapter 3 in to 6 in 76 152mm Top Vent Kit B Vertical into Existing Class A Chimney We...

Страница 19: ...ace Concrete Cap 1 in 25mm clearance with firestop 6 in 152mm minimum Non combustible Hearth Pad Airtight clean out door Sheathing 2 in 51mm minimum Flashing 1 in 25mm clearance 1 in 25mm clearance wi...

Страница 20: ...h slots in convection blower mount and ash box Figure 20 2 Push up and slide forward CAUTION Never draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or gara...

Страница 21: ...exhaust outlet Do not put silicone inside of pipe Figure 21 1 2 Slide the adapter onto the rear exhaust outlet and adjust the assembly to the appropriate position 3 Install the vent pipe into the ada...

Страница 22: ...t for drywall or a 7 32 drill bit for plaster drill holes 3 Using a hammer tap in wall anchors 4 Route the wires through the opening in the base plate and hold the base against the wall while aligning...

Страница 23: ...E Due to the abrasive nature of a pellet appliance fire the logs are not covered under warranty Any placement variation other than shown here can cause excessive heat and shall void the appliance warr...

Страница 24: ...24 PART NUMBER 811 0872 Spark Arestor Cap Roof Flashing Storm Collar Joist Shield Firestop Double Wall Connector Pipe Figure 24 1 CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEI...

Страница 25: ...25 April 23 2019 7021 801B CASTILE FREESTANDING 8 Reference Materials A Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 26: ...26 April 23 2019 7021 801B CASTILE FREESTANDING Date of Service Performed By Description of Service...

Страница 27: ...7050 144 Log Right Rear 7050 143 Collar Offset Top Vent 812 3570 Damper 3 Inch Tall Vertical Installs Only PEL DAMP3 Y Damper 4 Inch Tall Vertical Installs Only PEL DAMP4 Outside Air Kit Rear 811 0872...

Страница 28: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...

Отзывы: