WARNING
Asphyxiation Risk.
• DO NOT CONNECT THIS APPLIANCE TO A
CHIMNEY FLUE SERVICING ANOTHER APPLI-
ANCE.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
May allow flue gases to enter the house.
Fire Risk
.
Inspection of Chimney:
• Chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be 6 inch (152mm)
UL103 HT.
WARNING
NOTICE:
In Canada when using a factory-built chimney it must
be safety listed,
Type UL103 HT (2100oF) [1149oC] CLASS
“A”
or conforming to
CAN/ULC-S629, STANDARD FOR
650oC FACTORY-BUILT CHIMNEYS.
Figure 4.5 - Factory-Built Exterior Chimney
Floor
Protector
Chimney
Connector
Insulated " T "
Flashing
Listed Termination Cap
Trim Collar on
Inside Wall
Listed Chimney
Storm Collar
Wall Support
Roof Brace (if required)
E. Factory-Built Chimney
The chimney can be new or existing, and must meet the
following minimum requirements.
• Must be a 6 inch (152mm) diameter (ID) high
temperature chimney listed to UL 103 HT (2100
o
F) or
ULC S629M.
• Must use components required by the manufacturer
for installation.
• Must maintain clearances required by the manufacturer
for installation.
• Refer to manufacturers instructions for installation.
Floor
Protector
Chimney
Connector
Ceiling Support
Listed Chimney
Listed Termination Cap
Storm Collar
Flashing
Figure 4.6 - Factory-Built Interior Chimney
Fire Risk.
Do NOT pack insulation or other combustibles between
spacers.
• ALWAYS maintain specified clearances around venting
and spacers.
• Install spacers as specified.
Failure to keep insulation or other material away from vent pipe
may cause fire.
WARNING
WARNING
Fire Risk.
Follow Chimney Connector Manufacturer’s Instructions
for Proper Installation. ONLY use connector within the
room, between appliance and ceiling or wall.
Connector shall NOT pass through:
• Attic or roof space
• Closet or similar concealed space
• Floor or ceiling
Maintain minimum clearances to combustibles