Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15
8
B. Clearances to Combustibles (UL and ULC)
A
B
C
D
E
F
G
H
I
J
INSTALLATION: Full Vertical
Single Wall Pipe
17.5 11.5 32.5
20
8
22.5
42
NA
NA
NA
Double Wall Pipe
15.5
9.5 29.5
16
4
18.5
42
NA
NA
NA
INSTALLATION: Horizontal
with 2 foot minimum vertical
Off Appliance Top
Single Wall Pipe
17.5 11.5 32.5
20
8
22.5
42
18
NA
NA
Double Wall Pipe
15.5
9.5 29.5
16
4
18.5
42
13
18 31.5
INSTALLATION: ALCOVE
Six inch (6”) (152mm) diameter listed Double Wall air
insulated connector pipe with UL 103 HT** Listed factory-built Class “A” chimney, or
a masonry chimney. (Manufactured home must be equipped with a spark arrestor).
Maximum depth of Alcove shall be no more than 48 inches (1219mm) with a minimum
height of 84.0 (2134mm) from floor to bottom of ceiling and the reference clearances.
**In Canada must comply with Standard CAN/ULC-S629-M87 for the 650°C Fac-
tory-built chimney.
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
G
A
B
ALCOVE SIDE VIEW
A
B
C
D
BACKWALL / SIDEWALL
J
I
ALCOVE TOP VIEW
E
F
E
F
CORNER INSTALLATION
G
H
90° OFF TOP
UP & OUT CEILING
CLEARANCE
STOVE TO CEILING
CLEARANCE
Figure 3.3
WARNING
Fire Risk.
•
Comply with all minimum clearance to combusti-
bles as specified.
•
Failure to comply may cause house fire.