October 14, 2013 

 

 

 

           7047-910 

 

 

 

         

                  19

5100 I-ACC

Figure 19.1

Figure 19.2

Figure 19.3

Remove ground terminal

Remove Strain Relief

G.  Blower Cord Installation on Left Side 

The blower cord is shipped to be installed on the right side

 

of the appliance.  You may relocate the cord so it is on the 

left side.  You will need to remove the wires, flip them over 

and remove and reverse the male and female terminals 

and re-install the wires.  The wire harness and components 

are located on the back side of the right side panel. 

Relocating Blower Cord to Left Side

1.  Remove the convection blower housing from the appli-

ance by removing the start-up air control knob and 

removing the four 9/32 inch Allen head bots that hold the 

housing to the appliance.

2.  Remove the green ground terminal from the housing by 

using a 11/32 inch wrench and Phillips head screwdriver.  

Figure 19.1

3. Disconnect all the wires from the switch, rheostat and 

power cord.  

Figure 19.2.

4.  Remove  the  strain  relief  with  pliers.    This  will  free  the 

power cord from the convection housing.  

Figure 19.3.

5.  Remove the control plate by removing the three Phillips 

head screws.  Remove the blank plate on the left side of 

the housing in the same manner.  Swap the locations of 

the control plate and blank plate and re-install all of the 

fasteners.  

Figure 20.1

6.  Remove the heat shield from the housing.   First remove 

the screw on the bottom of the housing that holds the 

heat shield support.  Second, remove the three flat head 

screws that hold the shield to the housing. 

Figures 20.2 

and 20.3.

7.  Gently rotate the shield up to expose the connections tat 

are made to the snap disc.  Disconnect the wires that 

attach to the snap dis. 

Figure 20.4.

8. Using pliers, pry on the tabs that retain the harness 

enough to remove the harness.  Do not disconnect the 

wires that go to the blower.  Place the harness under 

the tabs on the left hand side of the convection housing 

and bend them down enough until they hold the harness.  

Figure 20.5

9.  Using pliers remove the strain relief that is on the power 

cord.  Remove the cap that is on the hole for the strain 

relief and re-install on the right side.  Route power cord 

through the hole and reconnect the ground terminal to 

one of the screws that hold the control cover in place.  

Use the 11/32 inch nut that was used to hold the ground 

terminal on the other side.  Connect the white wire on 

the power cord to the long high temperature lead coming 

from the blower.  Connect the black wire to the white 

wire on the rheostat.  Locate the new cord grip which is 

included in the component pack and install on the power 

cord about 2 inches further down the cord than the previ-

ous cord grip was installed.  Snap the cord grip back into 

the housing.  

Figure 20.6.

10. See 

Figure 20.1

 as a reference to connect the remain-

ing wires as shown.

11 Reconnect the wire harness to the snap disc that is 

located on the heat shield.  Rotate the heat shield into 

position and reinstall the flat head screws and the sheet

-

metal screw that is on the bottom of the housing.

12. Ensure that nothing is in the way of the blower and plug 

the power cord into an outlet.  Make sure that when the 

switch is in ‘Auto’ position that the blower will not turn 

on when the rheostat is engaged.  If the blower turns on 

while in the ‘Auto’ position then the wires at the switch 

are reversed.  Simply swap them on the terminals and 

perform the test again.

Содержание 5100 ACC

Страница 1: ...pliance Do not overfire If heater or chimney con nector glows you are overfiring Overfiring will void your warranty Comply with all minimum clearances to combustibles as specified Failure to comply may cause house fire WARNING Fire Risk For use with solid wood fuel only Other fuels may overfire and generate poisonous gases i e carbon monoxide Installation and service of this appliance should be pe...

Страница 2: ...pplies Needed 5 E Inspect Appliance and Components 5 F Install Checklist 6 3 Dimensions and Clearances A Appliance Dimensions 7 B Clearances to Combustibles 8 C Locating Your Stove Chimney 9 D Chimney Termination Requirements 9 E 2 10 3 Rule 10 4 Chimney Systems A Venting Systems 11 B Inspections 11 C Larger Chimneys 11 D Masonry Chimney 11 E Metal Heat Circulating Masonry 13 F Prefabricated Metal...

Страница 3: ...tered trademark of Hearth Home Technologies Installation and use of any damaged appliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supplied with unit Do ...

Страница 4: ...nd national codes and regulations Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits CAUTION WARNING DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM May allow flue gases to enter the house Asphyxiation Risk Installation and use ...

Страница 5: ... air handler joints and seams taped or sealed Basement installations should be avoided D Tools And Supplies Needed Before beginning the installation be sure the following tools and building supplies are available Reciprocating saw Framing material Pliers High temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety gl...

Страница 6: ...height requirements Roof flashing installed and sealed Terminations installed and sealed Clearances Section 3 Pg 7 Combustible materials not installed in non combustible areas Verified all clearances meet installation manual requirements Mantels and wall projections comply with installation manual requirements Protective hearth strips and hearth extension installed per manual requirements Applianc...

Страница 7: ...6 11 16 in 678mm 9 1 8 in 232mm 21 3 16 in 538mm 20 3 4 in 528mm 12 1 16 in 306mm 30 5 8 in 762mm Surround Sizes A B Standard 43 in 1092mm 31 in 787mm Large 53 in 1346mm 34 in 864mm 20 1 8 to 23 1 2 in 512 to 896mm 15 34 to 19 in 399 to 483mm 7 7 8 in 200mm Figure 7 4 Side View With Optional Offset Adapter 3 Dimensions and Clearances A Appliance Dimensions NOTE Flue Collar size is 6 inch 152mm dia...

Страница 8: ... inch 152mm S635 flue liner required as per ULC S628 In USA a minimum 5 ft length 1 82m 6 inch 152mm diameter flue liner is required as per UL 1482 SIDE TRIM SIDE WALL TOP TRIM 27 1 4 692mm 32 1 4 819mm HEARTH EXTENSION USA 16 3 4 CANADA 24 3 4 629mm 40 11 16 1033mm FIREPLACE FRONT SURFACE USA 23 1 2 CANADA 25 1 2 648mm HEARTH EXTENSION 43 11 16 1110mm 12in max MANTEL No thermal protection require...

Страница 9: ...hrough the warm space enclosed by the build ing envelope This helps to produce more draft espe cially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures unev...

Страница 10: ...cm Minimum 3 ft 91cm Minimum Wall or Parapet Flat Roof E 2 10 3 Rule These are safety requirements and are not meant to assure proper flue draft This appliance is made with a 6 inch 152mm diameter chimney connector as the flue collar on the unit Changing the diameter of the chimney can affect draft and cause poor performance It is not recommended to use offsets and elbows at altitudes above 4000 f...

Страница 11: ...or cleaning and re installation When possible install an airtight clean out door to the rear of the smoke shelf A Venting Systems Chimney Connector It is also known as flue pipe or stove pipe It must be 6 inches 152mm minimum diameter stainless steel connector pipe Chimney The chimney can be new or existing masonry or prefabricated and must meet the following minimum requirements as specified belo...

Страница 12: ...Accordance with Insert Listing Follow Manufacturer s Instructions for Maximum Liner Extension Above Chimney Maximum 30 Degrees Offset in Chimney Combustible Floor Masonry Chimney Cont d This insert conforms with the UL 1482 and ULC S628 Canada in all respects and is approved to UL ULC safety standards for installation and use within a fireplace with a masonry chimney in accordance with NFPA 211 an...

Страница 13: ...flue collar and the chimney top The air flow of the factory built zero clearance fireplace system must not be altered The flue liner top support attachment must not reduce the air flow for the existing air cooled chimney system No dilution air is allowed to enter the chimney 1 Secure the fireplace damper in the open position If this cannot be accomplished it will be necessary to remove the damper ...

Страница 14: ...the fireplace opening the portion of the insert extending onto the hearth must be supported Manufacturer designed adjustable support kit can be ordered from your dealer Final approval of this installation type is contingent upon the authority having jurisdiction Fire Risk When lining air cooled factory built chimneys Run chimney liner approved to UL 1777 Type HT requirements 2100 degrees F Re inst...

Страница 15: ...perly Chimney heights exceeding 25 feet 7 62m from base of appliance may create an over draft situation Overdraft condition may create over firing Over firing may ignite creosote and or damage appliance and chimney WARNING A permit may be required for installations final approval is contingent of the authority having local jurisdiction Consult insurance carrier local building fire officials or aut...

Страница 16: ...burn properly Smoke spillage occurs when door is opened due to air starvation WARNING Option One Installation Instructions The outside air cover comes packaged with the component pack It is necessary to remove the blower housing and block off the room air with the outside air cover 1 Remove the appliance cover plate on outer can and discard and reuse the 4 screws 2 Install optional flex adapter to...

Страница 17: ...liner do not always align properly This situation may be remedied by using the optional offset adapter See Appliance Dimen sions page for the amount of distance this accessory can telescope between the flue collar and stove pipe liner 1 Remove the cast iron flue collar from the appliance and flip it upside down Using the larger 7 drill bit supplied drill through all 8 countersunk locations Figure ...

Страница 18: ...ng Figure 18 2 2 Insert the 5 16 bolts inside the cast flue and through the chimney mounting bar Securely tighten the nuts Fas teners are provided 3 Re install the tube channel assembly baffle board ceramic blanket and baffle protection channel F Surround Trim Kit Installation 1 Lay surround face down on a protected surface to pre vent scratching 2 Using a Phillips head screw driver attach the sid...

Страница 19: ... tat are made to the snap disc Disconnect the wires that attach to the snap dis Figure 20 4 8 Using pliers pry on the tabs that retain the harness enough to remove the harness Do not disconnect the wires that go to the blower Place the harness under the tabs on the left hand side of the convection housing and bend them down enough until they hold the harness Figure 20 5 9 Using pliers remove the s...

Страница 20: ...047 910 October 14 2013 5100 I ACC Figure 20 1 Figure 20 2 Remove Control Plate Remove Strain Relief Disconnect Wires to theSnap Disc Figure 20 3 Figure 20 4 Place Harness Under Tabs Figure 20 5 Figure 20 6 ...

Страница 21: ... sheet metal shears cut trim along the marked edge The cut edge fits under lip of top trim so it allows for some variance in your straight edge 5 The double sided tape that holds front and side trims to scissors has a particularly powerful bonding adhesive Adjustments are extremely difficult once trim has adhered to tape Do a dry run first without removing paper from tape 6 Place cut edge of trim ...

Страница 22: ...ts from each side of insert and use plumbers tape to secure to structure a washer may be required Re install bolts 3 Unit must be grounded with 8 solid copper grounding wire or equivalent and terminated at each end with N E C approved grounding device 4 The factory built fireplace must meet UM 84 HUD requirements for outside combustion air supply to the fireplace fire chamber and the chimney must ...

Страница 23: ...it 43 X 31 Black TRIMKIT 4331 BK Gold TRIMKIT 4331 GD Nickel TRIMKIT 4331 NL Surround 51 X 34 Order Trim Kit Seperately SP 51IACC LRG Surround Trim Kit 51 X 34 Black TRIMKIT 5134 BK Gold TRIMKIT 5134 GD Nickel TRIMKIT 5134 NL Offset Adapter OFFSET ADAPT Door Upgrade Kit Spring Handles And Hinge Pins Gold UK DRGD Nickel UK DRNL Outside Air Kit OAK ACC Adjustable Hearth Support 12 X 50 2 10 H ADJSPT...

Страница 24: ...Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc tions for safe installa tion and operation DO NOT DISCARD Please contact your Quadra Fire dealer with any questions or concerns For the number of your nearest Quadra Fire dealer log onto www quadrafire com CONTACT INFORMATION This produc...

Отзывы: