October 14, 2013
7047-910
17
5100 I-ACC
Flue Collar
Stove Pipe/Liner
Gasket
Figure 17.1
Figure 17.2
Figure 17.3
Figure 17.4
Cast Iron Flue Located on Appliance
Drill through all 8 countersunk
locations
Once distance is established, drill holes
and secure both chambers together.
Figure 17.5
B. Securing Stove Pipe/Liner to Flue Collar
1. There are 4 pre-drilled holes in the flue collar 90 degrees
apart. Attach the flue collar to the stove pipe/liner. If the
seal is questionable use high temperature sealant such
as stove mastic
Figure 17.1.
2. Attach gasket to bottom side of flue collar with a thin coat
of silicone.
C. Optional Offset Adapter Installation
In some installations the flue collar and stove pipe/liner do
not always align properly. This situation may be remedied
by using the optional offset adapter. See Appliance Dimen-
sions page for the amount of distance this accessory can
telescope between the flue collar and stove pipe/liner.
1. Remove the cast iron flue collar from the appliance and
flip it upside down. Using the larger #7 drill bit supplied,
drill through all 8 countersunk locations.
Figure 17.2.
2. Slide the gasket over the flue collar and attach it to the
offset adapter using the 8-32 flathead screws provided.
Figure 17.3.
3. Adjust the offset adapter to desired distance. Drill holes
through the lower chamber as shown in
Figure 17.4
using the small drill bit #26 provided.
4. Cut the gasket to the proper length and slide in between
the upper and lower chambers centered on the screw
holes. Attach the upper and lower chambers with screws
provided.
Figure 17.5
.