Quadlogic Controls Corporation manufactures a line of revenue-grade electricity meters and
metering systems that utilize our patented, two-way Power Line Communications
technology. For over 25 years, Quadlogic systems have used this patented technology to
transmit advanced meter data over the existing power lines in a building or service territory.
No additional communication wiring is required to transmit metered data to the Scan
Transponder (Quadlogic’s data collector). Because the system is read remotely via various
public or private communication means, meter readers are also not required. Building and
facility owners, property managers, and utility companies depend on Quadlogic meters to
provide all the data needed to bill customers, allocate energy costs, manage loads, and
make smart energy decisions.
P
OWER
L
INE
C
OMMUNICATIONS
(PLC)
Power Line Communications, or PLC, is a method of transferring meter data via the existing
electric power wires that serve each tenant in a building or customer on a utility grid.
Quadlogic employs a patented method of PLC to move large amounts of metered data for
residential and commercial and industrial (C&I) customers to a central collection point. This
robust technology dynamically responds to the varying electrical noise conditions normally
found on power lines or electrical distribution grids by changing frequency, phase etc. and is
therefore able to maintain highly reliable data communication, including passing through
distribution transformers. (Consult Quadlogic or local representative for project layout
assistance.) The MiniCloset-5c includes PLC communications as a standard feature. In most
installations, the meter data from the MiniCloset-5c is read remotely via PLC.
S
CAN
T
RANSPONDER
-5 (PLC D
ATA
C
OLLECTOR AND
C
OMMUNICATOR
)
When the MiniCloset-5c is read via PLC, one or more Scan Transponder-5’s are required. The
Scan Transponder-5 is the central data collector for Quadlogic metering systems. It
communicates with Quadlogic meters over the existing electric wires that serve each tenant
in a building or customer on a utility grid.
The Scan Transponder-5 collects a data block from each meter in the system. The block
contains all previously uncollected meter readings, interval readings and event logs. This
data is stored in a non-volatile memory buffer. At regular intervals, the billing system
communicates with the Scan Transponder-5 and uploads all of the information for billing or
analysis purposes.
The Scan Transponder-5 is a separate product and requires its own installation.
Содержание MiniCloset-5c
Страница 2: ... COPYRIGHT 2009 Quadlogic Controls Corporation MiniCloset 5c Installation Manual ...
Страница 6: ... COPYRIGHT 2009 Quadlogic Controls Corporation 2 ...
Страница 16: ...Chapter 3 Parts and Options COPYRIGHT 2009 Quadlogic Controls Corporation 12 ...
Страница 26: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 22 Figure 4 5 3 phase 4 wire wye wiring ...
Страница 27: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 23 ...
Страница 28: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 24 ...
Страница 33: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 29 ...
Страница 34: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 30 ...
Страница 38: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 34 Figure 4 9 3 phase 3 wire delta wiring ...
Страница 39: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 35 ...
Страница 40: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 36 ...
Страница 44: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 40 Figure 4 11 3 phase 4 wire 1EL wiring ...
Страница 45: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 41 ...
Страница 46: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 42 ...
Страница 50: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 46 Figure 4 13 1 phase 3 wire 1EL wiring ...
Страница 51: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 47 ...
Страница 52: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 48 ...
Страница 57: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 53 ...
Страница 58: ...Chapter 4 Installation COPYRIGHT 2009 Quadlogic Controls Corporation 54 ...
Страница 76: ...Chapter 8 Troubleshooting COPYRIGHT 2009 Quadlogic Controls Corporation 72 Figure 8 1 Vector Diagram ...
Страница 78: ... COPYRIGHT 2009 Quadlogic Controls Corporation 74 ...
Страница 81: ...Appendix COPYRIGHT 2009 Quadlogic Controls Corporation 77 Figure A 1 MC 5c with modem installation ...
Страница 82: ...Appendix COPYRIGHT 2009 Quadlogic Controls Corporation 78 ...
Страница 87: ...Appendix COPYRIGHT 2009 Quadlogic Controls Corporation 83 Figure A 2 MC 5c communication network RS 485 ...
Страница 88: ...Appendix COPYRIGHT 2009 Quadlogic Controls Corporation 84 ...
Страница 90: ...Appendix COPYRIGHT 2009 Quadlogic Controls Corporation 86 ...
Страница 91: ......
Страница 93: ...Dimensional Drawing ...
Страница 95: ...Residential Installation Diagrams US ...
Страница 108: ...Residential Installation Diagrams Canada ...