MAINTENANCE
63
Cleaning the Sensors
There are four sensors in the Tabber; the two media sensors located on the table of the
Tabber, the tab sensor on the applicator head, and tab web (bin) sensor on the head assembly.
These sensors should be clean and free of accumulated paper dust. Use a vacuum with a soft
brush attachment or dry compressed air to remove the dust.
WARNING
DO NOT USE CHEMICALS or ABRASIVES OF ANY KIND ON THE SENSORS
The sensor locations are as follows:
MEDIA SENSOR TAB SENSOR
WEB (BIN) SENSOR
(Located under this plate.)
Media Sensor Test
There are two LED’s located on the exit side of the Media Sensor.
Green LED ON
= Power Present
Orange LED ON
= No Paper (not interrupted)
Orange LED OFF
= Paper Present (interrupted)
If the orange LED is not on when there is no paper present, then the reflector may need to be cleaned.
If the orange LED comes “on” even when paper is present, then the sensor intensity may need to be
lowered. This is rare, but possible when high gloss media is being used. A qualified Service Technician
should make this adjustment.
Web (Bin) Sensor Test
There are two LED’s located on the exit side of the Tab Web Sensor.
Caution!
To avoid tabs being driven from the tab reel and or personal injury from moving
rollers, please be sure to press the Emergency STOP button, before testing the Tab Web Sensor.
Green LED ON
= Tabs/Stamp Present (interrupted)
Orange LED ON
=
No Tabs/Stamps Present