background image

Guidance and manufacturer’s declaration –  
electromagnetic immunity

The QRS

 Opti

 is intended for use in the electromagnetic environment specified below. 

The customer or the user of the QRS 

Opti

 should assure that it is used in such an 

environment.

Emissions test

IEC 60601 

test level

Compliance 

level

Electromagnetic environment – 

guidance

Conducted RF IEC 

61000-4-6

Radiated RF IEC 

61000-4-3

N/A

3V/m

80 MHz to 

2.5 GHz

N/A

3 V/m

Portable and mobile RF 

communications equipment should 

be used no closer to any part of 

the QRS 

Opti

, including cables, 

than the recommended separation 

distance calculated from the equation 

applicable to the frequency of the 

transmitter.

Recommended separation distance

d

 = [3.5/V

1

] √

P

d

 = [3.5/E

1

] √

P

  80MHz to 800MHz

d

 = [7/E

1

] √

P

    800MHz to 2.5GHz

where 

P

 is the maximum output 

power rating of the transmitter 

in watts (W) according to the 

transmitter manufacturer and 

d

 is the 

recommended separation distance in 

meters (m). Field strengths from fixed 

RF transmitters, as determined by an 

electromagnetic site survey

a

, should 

be less than the compliance level in 

each frequency range

b

. Interference 

may occur in the vicinity of equipment 

marked with the following symbol:

NOTE 1 – At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 – These guidelines may not apply in all situations. Electromagnetic propagation is affected by 
absorption and reflection from structures, objects, and people. 

a

  Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and 

land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be predicted 

theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, 

an electromagnetic site survey should be considered. If the measured field strength in the location in 
which the QRS 

Opti

 device is used exceeds the applicable RF compliance level above, the QRS 

Opti

 

device should be observed to verify normal operation. If abnormal performance is observed, additional 
measures may be necessary, such as re-orienting or relocating the QRS 

Opti

 device.

b

 Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

Recommended separation distances between portable and 
mobile RF communications equipment and the QRS 

Opti

 device

The QRS 

Opti

 device is intended for use in an electromagnetic environment in which 

radiated RF disturbances are controlled. The customer or the user of the QRS 

Opti

 

device can help prevent electromagnetic interference by maintaining a minimum 
distance between portable and mobile RF communications equipment (transmitters) 
and the QRS 

Opti

 device as recommended below, according to the maximum output 

power of the communications equipment.

Rated 

maximum 

output power 

of transmitter 

W

Separation distance according to frequency of transmitter m

150 kHz to 80 MHz

d

 = [3.5/V

1

] √

P

80 MHz to 800 MHz

d

 = [3.5/V

1

] √

P

800MHz to 2.5GHz

d

 = [7/E

1

] √

P

0.01

N/A

0.12

0.23

0.10

N/A

0.38

0.73

1

N/A

1.2

2.3

10

N/A

3.8

7.3

100

N/A

12

23

For transmitters rated at a maximum output power not listed above, the 

recommended separation distance 

d

 in meters (m) can be estimated using the 

equation applicable to the frequency of the transmitter, where 

P

 is the maximum 

output power rating of the transmitter in watts (W) according to the transmitter 
manufacturer.

NOTE 1 – At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 – These guidelines may not apply in all situations. Electromagnetic propagation is affected by 
absorption and reflection from structures, objects, and people.

13

12

Содержание Opti 24-hour ABPM

Страница 1: ...Opti 24 hour ABPM User Guide...

Страница 2: ...14 Setting Up the System 15 Hardware Requirements 15 Software Requirements 15 Powering the Opti for use 15 Installing the Opti Insight Software 16 Conducting an Ambulatory Blood Pressure Study 17 Pro...

Страница 3: ...P Goodwin J 2004 Validation of the Opti oscillometric 24 hour ambulatory blood pressure monitor according to the International Protocol for the validation of blood pressure measuring devices Blood Pr...

Страница 4: ...ndently programmable periods 5 10 15 20 30 45 60 90 and 120 minutes Size 120 x 70 x 32 mm Weight Approx 250 g including batteries Storage Conditions 20 c to 65 c 15 90 RH non condensing Data Connectio...

Страница 5: ...d potentially harmful injury to the patient WARNING Ensure batteries are inserted with the correct polarity Improper installation is a hazard WARNING Too frequent measurements can cause injury to the...

Страница 6: ...d manufacturer s declaration electromagnetic immunity The QRS Opti is intended for use in the electromagnetic environment specified below The customer or the user of the QRS Opti should assure that it...

Страница 7: ...xed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the QRS Opti device is used exceeds the applicable RF compliance level a...

Страница 8: ...age for two seconds 4 Three quick beeps 5 The number of BP readings in memory with flashing printer for three seconds 6 One long beep 7 Time flashing for twenty seconds The monitor is now ready to be...

Страница 9: ...onducting an Ambulatory Blood Pressure Study Communicating with the Opti To successfully complete an ABP study you need your computer to be able to communicate with your ABP monitor in order to progra...

Страница 10: ...allowed Time Intervals None 5 10 15 20 30 45 60 90 and 120 minute intervals between readings Fitting a patient with the Opti and OptiFit blood pressure cuff After you have successfully programmed the...

Страница 11: ...erify that the monitor operates correctly Finishing the study If you wish to finish the study before the patient returns instruct the patient to turn off the monitor by holding down the Start Stop but...

Страница 12: ...for servicing 99 Service Required EEPROM calibration data CRC failure Unit needs to be recalibrated Return for servicing In the event you are unable to rectify the error and need assistance please ca...

Страница 13: ...entative To return for service please send to QRS listed on Limited Warranty page 25 care of Customer Care Limited Warranty Opti Ambulatory BP Monitor QRS provides to the original purchaser the follow...

Страница 14: ......

Страница 15: ...Date 03 12 Advena Ltd 33 Bridge St Hereford HR4 9DQ UK 610001 00A 6901 E Fish Lake Road Suite 188 Maple Grove MN 55369 1 800 465 8408 1 763 559 8492 Fax 1 763 559 2961 info QRSdiagnostic com www QRSdi...

Отзывы: