31
4
31
b.
Indoor/Outdoor connection cable should be H07RN-F type, 2,5 mm².
c.
To mount the cable to the interior unit: Remove the front panel and the cover plate of the terminal
strip on the right hand side of the interior unit. Figure 14.
Figure 14
Terminal block
cover
Cable clamp
d.
The cable can be fed through from the back of the interior unit to the terminal strip.
e.
Connect the electrical wires to the terminal strip. All wiring must be performed strictly in accordance
with the wiring diagram located on the back of the indoor unit's front panel.
f.
Attach the cable of the indoor unit. Remove the cover plate of the terminal strip of the outdoor unit.
g.
Connect the connection cable to the terminal strip. All wiring work must be performed strictly in
accordance with the wiring diagram located inside of wire cover of the outdoor unit .
h.
The earth cable must be connected directly to the metal plate on which the terminal strip is mounted.
The location is indicated with the symbol
i.
In models with a capacity of up to 6.0 kW, the supply cable is already preassembled on the inside
part. In models with a capacity > 6.0 kW, the supply cable must be connected to the outside part (the
supply cable is not included).
j.
Only connect the power supply cable once the entire installation of the air conditioner has been
completed.
G
TAKE CARE
For models with a capacity < 4.5 kW plug the plug into a wall socket.
For models with a capacity > 4.5 kW connect the power supply cable directly the power source.
Do not use a plug and socket as the high current can damage both the terminals of the plug and
the socket and even cause a fire.
12. EVACUATING THE COOLING SYSTEM
Air and moisture that remain in the refrigerant system, e.g. after installation, can cause undesirable effects
or damage as indicated below:
•
Pressure in the system rises.
•
Operating current rises.
•
Cooling or heating efficiency drops.
•
Moisture in the refrigerant circuit may freeze and block capillary tubing.
•
Water may lead to corrosion of parts in the refrigeration system.
•
Damage of the compressor.
Therefore, the indoor unit and tubing between the indoor and outdoor unit must always be leak tested
and evacuated with aid of a vacuum pump to remove any noncondensables and moisture from the system.
Screw
Wire box cover
Screw
Instal_S70xx ('21) V1.indd 31
Instal_S70xx ('21) V1.indd 31
08-11-2021 18:12
08-11-2021 18:12
Содержание S 7026
Страница 17: ...6 17 Instal_S70xx 21 V1 indd 17 Instal_S70xx 21 V1 indd 17 08 11 2021 18 12 08 11 2021 18 12 ...
Страница 49: ...u 49 Instal_S70xx 21 V1 indd 49 Instal_S70xx 21 V1 indd 49 08 11 2021 18 12 08 11 2021 18 12 ...
Страница 65: ... 65 Instal_S70xx 21 V1 indd 65 Instal_S70xx 21 V1 indd 65 08 11 2021 18 12 08 11 2021 18 12 ...
Страница 66: ...66 Instal_S70xx 21 V1 indd 66 Instal_S70xx 21 V1 indd 66 08 11 2021 18 12 08 11 2021 18 12 ...
Страница 67: ...67 Instal_S70xx 21 V1 indd 67 Instal_S70xx 21 V1 indd 67 08 11 2021 18 12 08 11 2021 18 12 ...