![Qimarox PRORUNNER Mk5 Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/qimarox/prorunner-mk5/prorunner-mk5_user-manual_3168672082.webp)
Maintenance vertical conveyor
82
UM-PRORUNNER_Mk5-1.2-EN-US
7.8.12
Replace the motor reductor
Uninstall the motor reductor
1.
Remove the motor reductor (A) from the
reactor bar (B).
2.
Remove the motor reductor (C) from the
axle.
Uninstall the main shaft
1.
Remove the main shaft (A) from the
bearing.
B
A
Note
Make sure that the key (D) does not
fall.
C
D
A