3.9 AutoPing and Power Reboot:
Each power outlet has optional settings that a NP system uses to ping network equipment.
The pinged equipment is attached to a specific power outlet. It reboots user equipment
power source if a network connection is not detected any more. However, user equipment
never gets power reboot if the equipment never replies ping reply to a NP system.
A power outlet has the optional settings (Power Outlet Setup Menu) that specify the
destination IP address that the system will ping periodically, and maximum network
downtime allowed. In addition, to avoid unwanted reboots, a NP system also pings the
gateway IP address (as default) to make sure a NP system has a network connection that is
still active. Otherwise, AutoPing will be in off mode if a NP system lost network connection.
To change the default gateway IP address as ping destination, use TCP/IP Configuration
Menu to enter your desired destination address.