QED CRT410 Скачать руководство пользователя страница 3

Remove all packaging and check that there has been no transport damage.
Any transport damage, must be reported to the transport company and noted on the delivery note.

To ensure correct function it is important that the cabinet is level.

For cabinets fitted with lockable wheels, ensure that the wheels are locked and are tucked
underneath the footprint of the appliance

In the case of installing the cabinet into fixed room fittings:

150 mm of free space must be left behind and above the cabinet in order for the cooling
system to operate satisfactorily.
There must be sufficient space at the hinge side to allow proper cleaning and removal /
replacement of the shelves

Place the cabinet in a dry and ventilated place.
Keep the cabinet away from heat sources and do not expose it to direct sunlight.
Using the cabinet in an ambient temperature that reaches extremes of cold (for example in goods
bay where the temperature is largely affected by the outside) may affect the internal temperature
regulation.

Important:

 Before it can be turned on for the first

time, the transport safety strap must be removed from
the compressor. Access the compressor compartment
from behind the unit. The strap is held on by two cross
headed screws at either end (see fig. 1)

Remove these carefully as there will be some spring in
the strap. The strap should be saved for future use (if
the cabinet is to be moved to another site) or recycled
responsibly.

fig. 1

Start up

Before use, it is recommended that the cabinet is cleaned; see the section on maintenance and
cleaning.

Important:

If the cabinet has been placed horizontally, tilted or shaken during transport, please wait

2 hours once the cabinet is level before starting it for the first time.

When ready, connect the plug to a suitable, accessible socket and turn the cabinet on, using the
power switch in the control panel

Unpacking and Installation

MCRTL21.1                                                                                                                                                                          3

Содержание CRT410

Страница 1: ...USER MANUAL CRT410 CRT640 CRT900 CRT1250 CONTROLLED ROOM TEMPERATURE CABINETS ...

Страница 2: ...ces or anæsthetic or other flammable gasses Power supply The cabinet is designed for 220 240 V 50 Hz The appliance must be correctly earthed The cabinet is fitted with a B S 1363 UK mains plug A 13 amp fuse must be used The flexible cord fitted has three cores The colours used are Green Yellow Earth Blue Neutral Brown Live Do not use this appliance with multi socket distribution extension leads Ex...

Страница 3: ... that reaches extremes of cold for example in goods bay where the temperature is largely affected by the outside may affect the internal temperature regulation Important Before it can be turned on for the first time the transport safety strap must be removed from the compressor Access the compressor compartment from behind the unit The strap is held on by two cross headed screws at either end see ...

Страница 4: ...ay will flash followed by the highest recorded temperature If is pressed again the display will flash followed by the current chamber temperature Pressing again will return to and the menu will cycle as described above If the buttons are not touched for 10 seconds the screen will return to normal Resetting the Recorded High Low Values Display the value that you would like to reset or as described ...

Страница 5: ... desired from the main screen press P The screen will alternate between and the current set point Use the arrows to adjust it and press P again to confirm Please note that the set point is limited to between 17 and 21 C If the monitored temperature is regularly reaching outside Controlled Room Temperature limits causing high or low alarms please call your supplier for technical assistance Please n...

Страница 6: ... cleaning If it becomes damaged and the cabinet fails to cool please call your supplier for technical assistance Disconnect from the mains power supply before cleaning Monthly use only a light soap solution to clean the internal and external surfaces of the cabinet Do not use any abrasives or cleaning product containing chlorine or other harsh chemicals as they can damage the surfaces and the cool...

Страница 7: ...t changed since before the problem make a note of the details chamber temperature high and low temperatures ambient temperature any alarms etc and call your supplier for technical assistance If the cooling system becomes damaged and the cabinet fails to cool disconnect the appliance from the power supply and call your supplier for technical assistance All work on or repairs to the cooling system m...

Страница 8: ...Unit 21 Botany Business Park Macclesfield Road Whaley Bridge High Peak SK23 7DQ T 01663 735494 www qedscientific com MCRTL21 1 ...