50
OPERATION AND MAINTENANCE MANUAL
QTS SERIES
Twin Screw Positive Displacement Pump
QTS-M
08
QTS-M
08
MAI
N
T
E
N
AN
C
E
14.
Cavitation of the pump can cause noise and vibration which can damage the mechanical
seals. If cavitation is detected, gather all system information available and verify the application.
Remember that your equipment was selected for a particular application and any other use
without prior consent may result in damages that can avoid the pump warranty.
15.
When assembling the rotors they should be contact free.
16.
Rotors are inside the casing and their front faces must be aligned.
17.
Use the torque values (according to the pump model) on the components that are indicated.